INSTALLATION INSTRUCTIONS
LOG SET DIAGRAM - IS700
1
2
3
4
5
6
7
11
The Gas Log Kit contains the following:
1)
Rear Log
2)
Middle Log
3)
Front
Log
4)
L/H
Side
Log
5)
L/H
Cross
Log
6)
R/H
Side
Log
7)
R/H
Cross
Log
INSTALLERS - PLEASE NOTE
(A) LOG
SETTINGS
Do not remove logs from heater unless absolutely necessary!! Logs have been preset and aligned for
correct performance. Only place cross logs in position as per instructions above.
Please Note:
Accurate placement of logs is critical for correct performance of heater. Please ensure
the rear log is hard up against the rear at the firebox at the base and at the top.
(B) GAS PRESSURE FOR LPG
Do not adjust gas burner pressure on LPG. Gas burner pressure has been set at factory to required
gas burner settings for LPG.
(C) GAS PRESSURE FOR NATURAL GAS MUST BE CKECKED
For Natural Gas please check and adjust gas burner pressure if required as inline pressure can vary in
areas of Australia. For Natural Gas burner pressure settings refer to Page 4. This is very important
for getting the correct performance from the heater.
(D) ADJUSTMENTS
This product has been fully tested for its operation sequences and performance at the factory and no
adjustments should be made, except for the above mention of Natural Gas, to the appliance unless
approved by the manufacturer.