background image

12V Diaphragm Water Pump - PRP-125  

 

Maintenance and Troubleshooting 

 

Take precautions to prevent injury due to contact with chemicals. • If the pump has been 
used to pump chemicals, flush it with clean water or neutralizing agent before servicing

.

 

Disassembly/Assembly (Pump Head) 

 

No.  Qty.  Description 

 

No.  Qty.  Description 

Switch cover screw 

 

Electrical connection lead 

Pump head screw 

 

Pressure switch  

Pump head 

 

Pressure switch screw 

Motor 

 

Pressure switch cover 

 

1.  Disconnect power to the pump motor. 

2.  Remove the pressure switch cover screw (

1

) and then remove the cover (

8

). 

3.  Disconnect the red wires (

5

) from the pressure switch. 

4.  Remove the screws (

2

) from the front of the pump head (

3

). 

5.  Slide the pump off the motor (

4

) assembly. 

Reassembly (Pump Head to Motor) 

1.  Align the pump head (

3

) screws tabs to the motor (

4

) and secure it with the pump head screws (

2

). 

Tighten the screws, being careful not to over-tighten as the material is ABS plastic. 

2.  Reconnect the red wires (

5

) to the pressure switch (

6

). Wires can be connected to either terminal. 

3.  Install the pressure switch cover (

8

) with the pressure switch cover screw (

1

). Tighten the screw, 

being careful not to over-tighten as the material is ABS plastic. 

4.  Reconnect the pump plumbing. 

5.  Follow the start-up procedure. 

Summary of Contents for PRP-125

Page 1: ...12V Diaphragm Water Pump PRP 125 User Manual Revision 1 0 September 2016 RETAIN THIS MANUAL FOR FUTURE REFERENCE PLEASE READ THIS MANUAL CAREFULLY BEFORE USE...

Page 2: ...low all electrical and safety codes Make certain the power source conforms to the pump voltage requirements Ensure that all power sources are disconnected before installing the pump Improper duty cycl...

Page 3: ...nstallation 4 Mounting 4 Plumbing 5 Electrical Connection 5 Operation 6 Start Up 6 Demand Operation Intermittent Duty 6 Bypass Operation If Equipped 6 Maintenance and Troubleshooting 7 Disassembly Ass...

Page 4: ...ffects It is intended for intermittent duty cycles but can also be run continuously for short periods of time The higher the duty cycle the shorter the expected life of the pump Typical pump usages in...

Page 5: ...ntering the pump Failures due to foreign debris entering the pump will not be covered under warranty The pump comes with 90 tube connectors that can be used for easier plumbing To attach firmly push t...

Page 6: ...configuration Start Up To start and prime the pump the outlet line must be open allowing any in the pump to escape This is to avoid the possibility of airlock The pressure switch will shut off the pum...

Page 7: ...essure switch cover screw 1 and then remove the cover 8 3 Disconnect the red wires 5 from the pressure switch 4 Remove the screws 2 from the front of the pump head 3 5 Slide the pump off the motor 4 a...

Page 8: ...let tubes and connections and ensure they are air tight Debris in the check valve Clean obstructed or jammed check valves Ruptured pump diaphragm Replace pump diaphragm Defective pump check valve Repl...

Page 9: ...pump diaphragm Defective pressure switch Replace pressure switch Low Flow Rate and Pressure Possible Fault Action Air leak at the pump intake Check inlet tubes and connections and ensure they are air...

Page 10: ...10 Technical Specifications Inlet 10 mm or 1 4 hose fitting Outlet 10 mm or 1 4 hose fitting Flow 1 6 GPM 6L min Volts 12V 9 to 14 4V Amp Draw 2 1A Max 6A Pressure 80 PSI Motor duty cycle will vary w...

Page 11: ...ining course before being given access to the product The product has been supplied by a general merchandise retailer that may not be familiar with your specific application or your description of the...

Reviews: