PWM operating mode
(Pulse-Width Modulation)
By changing the hysteresis settings
(chapter "Configuration settings"),
we can turn on
the PWM operating mode.
In this mode, AURATON Auriga cyclically switches on the heating device in order to
minimize temperature fluctuations. AURATON Auriga checks the temperature rise times
and the temperature drop times.
Knowing these values, AURATON Auriga turns the heating device on and off in such
cycles to keep the temperature as close as possible to the set value.
1. Temperature
2. Time
3. Set temperature
4. Room temperature
NOTE:
In PWM mode, AURATON Auriga can turn on the heating device despite the fact
that the temperature in the room is higher than the set temperature. This is due to
the PWM algorithm that aims to maintain the set temperature and anticipate the
behavior of the thermal system.