Hysteresis change
The hysteresis is to prevent too frequent switching on of the actuator due to small
temperature fluctuations.
For example, for the HI 2 hysteresis, when the temperature is set to 20 ° C, switching
on will take place at 19.8 ° C, and switching off at 20.2 ° C. For the HI 4 hysteresis,
when the temperature is set to 20 ° C, switching on will take place at 19.6 ° C, and
switching off at 20.4 ° C.
To switch to the hysteresis change
mode, hold down the
e
,
&
and
f
buttons simultaneously for 3
seconds. The hysteresis change mode
is signaled by the
HI
inscription . Use
the
e
and
f
buttons to change the
hysteresis settings.
HI 2
- ± 0.2 ° C
(factory set)
HI 4
- ± 0.4 ° C
HI P
- PWM operating mode
(chapter
"PWM operating mode").
Confirm your choice by pressing
g
.
AURATON Auriga will return to normal
operation.