25
24
Cooperation with the AURATON 2030 RTH regulator and/or
the AURATON T-2 thermometer as well as the AURATON H-1 handles
By default, the
AURATON RTH
receiver does not have any
AURATON H-1
handle or AURATON W-1 window position sensor paired, therefore the relay
is controlled by the paired
AURATON 2030 RTH
regulator and/or the
AURATON T-2
thermometer. When at least one
H-1
handle is paired with the
RTH
receiver, the relay is controlled in the following manner:
A) The window is closed or trickle-ventilated (micro-ventilation)
.
When the
H-1
window handles paired with the receiver, and all windows
are closed or trickle-ventilated, the relay still maintains the setpoint from
the paired
AURATON 2030 RTH
regulator and/or the
T-2
thermometer.
B) The window is pivoted
.
If at least one window is pivoted, the temperature set in the
AURATON
2030 RTH
regulator is lowered in
AURATON RTH
receiver down to 3°C.
This state will be maintained until closing. This state will last until all
windows are closed or trickle-ventilated
.
C) The window is opened
.
When you open a window equipped with the
H-1
handle paired for longer
than 30 seconds, the relay in the
AURATON RTH
receiver is switched off,
as is the connected heating device. If all the assigned windows are again in
a state other than “opened”, the
RTH
receiver returns to normal
cooperation with the
AURATON 2030 RTH
regulator and/or the
T-2
thermometer no earlier than 90 seconds after switching off the relay. The
purpose of this delay is to prevent too rapid transitions of the connected
heating devices between the ON and OFF states. However, if the
temperature in the room drops below 7 °C, the relay inside the receiver is
switched on regardless of the positions of windows in order to prevent
the room from freezing.
D) The signal is lost
.
When the
RTH
receiver has lost the signal from the
H-1
handle paired
(3 consecutive transmissions are lost), it changes the status if this window
to “closed”. When the transmission is restored, the
H-1
handle is again
properly read off by the
RTH
receiver.
Special situations
ź
When 3 consecutive transmissions (after 15 minutes) from the
AURATON
2030 RTH
regulator and/or the
T-2
thermometer are lost, an error is
signalled on the
RTH
receiver (LED flashing continuously red and green).
The
RTH
receiver starts executing the ON - OFF cycle memorised during
the last 24 hours of operation until the problem is removed.
ź
When both signals return (from the
AURATON 2030 RTH
regulator and
the
T-2
thermometer), the error is cancelled and the receiver enters its
normal mode of operation.
ź
When only the
T-2
thermometer signal returns, the receiver uses the last
memorised setpoint value and maintains it while signalling the error.
ź
When the
H-1
handles, the
T-2
thermometer and the
AURATON 2030 RTH
regulator (the temperature is measured with the
T-2
thermometer) are
paired with the receiver, then maintaining the work cycle from the last 24
hours occurs only after losing the signal from the
T-2
thermometer. When
only the signal from the
AURATON 2030 RTH
is missing, the RTH receiver
automatically maintains the last memorised setpoint from the
AURATON
2030 RTH
regulator and also signals an error.
ź
When you have only the
H-1
handles and the
T-2
thermometer paired with
the
RTH
receiver without the
AURATON 2030 RTH
regulator, the
RTH
receiver maintains a constant, factory-defined temperature of 20°C. If you
pivot any window equipped with the
H-1
handle paired with the receiver,
a temperature of 17°C is maintained. If you open any window equipped
with the
H-1
handle paired with the
RTH
receiver, the receiver switches off
the heating device, but will switch it back on when the temperature falls
below 7°C.
RESET of the regulator
Pressing the
RESET button
( ) causes the time and day setting to be erased,
and the regulator to be restarted.
MASTER RESET of the regulator
The MASTER RESET function restarts the regulator and restores factory
settings. This function is invoked by pressing the
and
RESET buttons
simultaneously.
NOTE: All user-defined programs will be erased!
OK....