1.2 Wiring
AURATON 2005
Wiring terminals are at the back of the thermostat.
Press down the terminal cover, you can find three
terminals which labelled COM, NO and NC. It is a
typical single-pole, double throw (SPDT) contact. In
most COM and NO are used.
1.3 Mounting the thermostat
AURATON 2005
Use the template provided, drill two
Ø
6mm holes on
the wall. Insert the wall anchors and tighten the left
screw with 3mm clearance.
NO
COM
NC
NO
COM
NC
Fix the thermostat by putting it over the screwhead
and slide it rightward (note the keyhole like opening
at the back of the thermostat). Tighten the remain
screw to lock it in place.
Note:
If the wall is made of wood, there is no need to use the
wall anchors. Drill two
Ø
2.7mm holes instead of
Ø
6mm.
AURATON 2005
- Installation
31
EN