AURATON 2005 TX RX Plus
- Setting communication code
4. Press and hold "PROG#" again to set new
communication code (range between 001 to
255).
5. Plug in receiver
AURATON 2005 RX Plus
to
230VAC and press OK button on the transmitter
AURATON 2005 TX Plus
(after 10 seconds
LCD will return to normal mode).
6.
AURATON 2005 RX Plus
will confirm
programming new code by blinking yellow diode
for 3 seconds.
7. Plastic holder for
Auraton 2005 TX plus
There is a plastic holder for
AURATON 2005 TX
Plus
in the box.
Notes:
If
AURATON 2005 RX Plus
will not receive ON/OFF
signal from
AURATON 2005 TX Plus
for 5 minutes
(cycles) the heating device will be turned off.
System will return to its normal operation after
interfere disapear.
AURATON 2005 TX Plus
sends
digital signals that is why many other devices can
work within its range without interfere.
6. Setting communication code
There is a factory set communication codet - „085”.
In case of interfere with other device (e.g. another
AURATON 2005 TX Plus
) preset code can be
changed:
1. Unplug receiver
AURATON 2005 RX Plus
from
230VAC.
2. Slide transmitters
AURATON 2005 TX Plus
cover.
3. Press and hold "PROG#" for 2 seconds,
communication code will be displayed on LCD
(factory set code is 085).
41
EN