USER’S MANUAL

EN

200 TRA

Summary of Contents for 200 TRA

Page 1: ...USER S MANUAL EN 200 TRA ...

Page 2: ...eceiving information about the current temperature in the room and the preset temperature There can be any number of radiators with Auraton TRA heads in a room but all must be paired with the same Auraton 200 TRA controller If the number of the Auraton TRA heads is larger the speed of response of the radiators to changes of temperature in the room increases which is very beneficial FrostGuard func...

Page 3: ...dge or on off key temperature decrease key hold controller on off short press acknowledge temperature setting temperature increase key temporary temperature decrease mode keys AURATON 200 TRA temperature controller explained ...

Page 4: ...y temperature decrease mode programming indicator WIndicates the temporary temperature decrease mode planned by the user Displayed when the mode is not executed but the function of the temporary temperature decrease is active refer to Temporary temperature decrease setting section for more details 5 Transmission symbol Indicates communication with the receiver 6 Battery exhausted Displayed when th...

Page 5: ...stall it back NOTE We recommend using alkaline bateries to supply AURATON controllers Rechargeable batteries should not be used because their rated voltage is too low Controller location largely affects its proper operation When located in a place without air circulation or exposed to direct sunlight the controller may not control the temperature properly The controller should be located on an int...

Page 6: ...rilled holes 4 Screw the back of the controller enclosure to the wall with the two screws provided 5 Install the batteries and replace the controller enclosure NOTE No expansion bolts are needed for wooden walls Just drill holes diameter 2 7 mm instead of 6 mm and screw the screws directly into the wood The controller can be mounted to a smooth surface with e g two sided adhesive tape The controll...

Page 7: ... keys set the desired temperature with the accuracy of up to 0 2 C 3 Press the ok key to acknowledge selection AURATON 200 TRA controller features the special FrostGuard function to protect the room from possible freezing The function is activated when the controller is switched off With the controller switched off when the room temperature drops to 2 C the Fr symbols will appear and signal will b...

Page 8: ... time will decrease the set temperature in a normal mode by 3 C for 6 hours NOTE After 6 hours the controller will return to the main temperature setting Instead of the moon symbol the sun symbol will be displayed NOTE The temporary temperature decrease mode always starts when the function is turned on This means that the possible temporary temperature decrease has to be set at the time you want i...

Page 9: ...9 Description of the AURATON TRA head battery cover closing button signaling diode The AURATON TRA head works with the wireless controller AURATON 200 TRA The head is installed directly on the radiator ...

Page 10: ... reduction fitting A onto the insert delivered with the head all the way b Take off the head battery cover using a flat screwdriver c Install two AAA batteries in the head paying attention to their polarity The pin of the head moves to the fully open position which is necessary for installation of the head on the reduction fitting d Slide the safety ring into the released position e Slide the head...

Page 11: ...osition g Pair the head with the Auraton 200 TRA unless pairing has been done earlier h Close the head battery cover Installation on the head with a Danfoss RA N insert In order to install the Auraton TRA head on a radiator with a Danfoss RA N insert perform the following procedure c Perform steps b through h in the chapter titled Method of installation of the TRA head on a radiator with an M30x1 ...

Page 12: ... for more than 3 s 3 After 3 s the Auraton 200 TRA controller sends pairing data to the Auraton TRA head which the head indicates with three beeps 4 After successful pairing of the Auraton 200 TRA with the head close the battery cover if installed on the radiator Resetting the Auraton TRA head to the default settings a take off the head battery cover b take out the battery one of the two or both c...

Page 13: ...nstalled after 3 s Even after communication between the head and the Auraton 200 TRA controller is interrupted the user should not experience any deteriorated adjustment of temperature In such a case the head stabilizes the temperature of the radiator on the level that was required earlier in order to maintain the temperature in the room Signaling after startup of the head After the battery is ins...

Page 14: ... affect adjustment of temperature The head indicates low battery status by blinking the LED twice every 8 s Also when the battery becomes even more discharged the head starts emitting two beeps every 8 minutes In order to switch off the beeping for 1 day press any key on the Auraton 200 TRA controlled paired with the head or lift the head flap for 2 s and reinstall it Calibration error signals Aft...

Page 15: ...Default temperature setting 20 C Additional function FrostGuard Operating cycle 24 hours Operation status control LED diode sound head LCD controller Power supply of AURATON 200 TRA 2 alkaline AAA 1 5 V batteries Power supply of the TRA head 2 alkaline AAA 1 5 V batteries Radio frequency of the TRA 868 MHz Range of operation the TRA in a regular building with standard wall structures approx 30 m i...

Page 16: ...www auraton pl ver 20190118 ...