Selecting proper location for AURATON 200 RTH
temperature controller
Controller location largely affects its proper operation. When located in a
place without air circulation or exposed to direct sunlight, the controller may
not control the temperature properly. The controller should be located on an
internal wall of a building (partition wall) in a place with free air circulation.
Avoid locations near sources of heat (TV set, heater, refrigerator) or places
exposed to direct sunlight. Location near doors and the resultant vibration
may cause the controller to function improperly.
Battery installation / replacemen in AURATON 200 RTH
Battery sockets are located inside the controller on both sides of the display.
To install the batteries, remove the controller enclosure as shown in the
figure.
Place two AAA 1.5 V batteries in the battery socket observing
the correct polarity.
AURATON RTH
cable tie clamp
control connection terminal
(a terminal for fastening a two-core
cable of the heating or air
conditioning
device to be controlled
button for deregistering
already paired devices
button for pairing devices
with the RTH receiver
LED indicating operation
of the device
cable tie clamp
power supply terminal
~230V
AC
legend
The LED light’s green
– the output device is off
(the contacts
COM
and
NC
are closed)
.
The LED light’s red
– the output device is on
(the contacts
COM
and
NO
are closed)
.
The LED flashes green
– the
RTH
receiver awaits the device
to be paired
(chapter: “Pairing the AURATON 200 RTH wireless
regulator and the RTH receiver”).
The LED flashes red
– the
RTH
receiver awaits the device
to be deregistered
(chapter: “Deregistering the regulator from the
RTH receiver”).
The LED flashes alternating red and green
:
ALARM -
the
RTH
receiver has lost connection with one of the paired
devices
(chapter “Special situations”).
RESET -
receiver deregisters all previously paired devices -
(chapter
“Deregistering all devices paired with the RTH receiver”).
Legend - description of LED signalling
hole for fastening
the receiver
to the wall with a screw
hole for fastening the receiver
to the wall with a screw
Description of the AURATON RTH receiver
The
AURATON RTH
receiver cooperates with the
AURATON 200 RTH
wireless
receiver. The receiver is installed on the heating or air conditioning device and can
operate under the load of 16 A.
~