15
Figure 10: Bolted Grounding
3.1.2
3.1.2
3.1.2
3.1.2
Using Certified Grounding Device for Grounding
Using Certified Grounding Device for Grounding
Using Certified Grounding Device for Grounding
Using Certified Grounding Device for Grounding
Use grounding device tested and certified by third-party certification institutes that are
suitable for use in solar photovoltaic systems. The grounding shall be implemented in
accordance with the regulated method of the manufacturer of the grounding device and the
manufacturer must ensure the grounding performance of the grounding device.
3.2 System Grounding Method
To achieve optimal system performance, it is recommended to ground the negative (or
positive) pole of the solar photovoltaic system array. Failure to correctly ground the system
will lower system performance and void the AUO Photovoltaic Module's limited warranty on
output. Please connect grounding in accordance with IEC Standards or the electrical codes
and regulations of the site/country of installation to ensure that the system is correctly
grounded.
System negative pole grounding: PM060, PM072 product series.
System positive pole grounding: PM096 product series.