3.1 AC Cable Termination
Remove the protective sticker located on
the Mid-Cable Receptacle(MCR) and
connect this receptacle to the AC cable of
the next module. Press the Male – Female
plug firmly into the receptacle until you
hear the lock click into place. Continue to
connect subsequent modules to the end
of the string.
3.2 AC Cable Management
The following diagram shows a system of three AC Unison modules. The AC cables are secured to the
module frames with stainless steel Cable Clips at the recommended locations below
.
Limit module
spacing to 1 inch maximum. Please ensure that all AC wiring is well secured and not in contact with the
roof surface.
3.0 AC Unison Module System Installation
Firmly press male AC cable into rigid female
MCR AC receptacle
1 inch maximum
module spacing