2.3 AC Unison Field Preparation
Step 1 Attach Mid-Cable
Receptacle(MCR) to Module
Frame
t
Attach the stainless steel (SS) MCR bracket
to the module frame with two M5 screws
(provided). Torque to 20 inch-pounds. Next,
attach the AC Mid-Cable Receptacle harness
to the SS MCR bracket with two M3 screws
(provided). Torque to 20 inch-pound. It is best
to complete steps 1 and Step 2 on the ground
prior to installing the AC Unison modules.
Step 2
First and last module
considerations
For the last module in the circuit, insert the End
Cap into the Mid-Cable Receptacle.
For the first module in the circuit, connect the
AC cable plug to Transition Table.
*For additional information on AC Module Planning&Preparation, please see page
xx.