![Aumuller KS 15 1000 S12 Assembly And Commissioning Instructions Download Page 21](http://html1.mh-extra.com/html/aumuller/ks-15-1000-s12/ks-15-1000-s12_assembly-and-commissioning-instructions_3016550021.webp)
21
Assembly Instruction
KS 15 S12 24V DC
E
LECTRIC
C
ONNECTION
Make sure when establishing the connection
that there is no voltage at the terminals!
Unused wires must be safely insulated!
I
NSTALLATION
STEP
8:
E
LECTRIC
C
ONNECTION
Direction of travel
OPEN
CLOSE
polarity reversal
+
+
-
-
Wire colour coding
Colour
DIN IEC 757
white
WH
brown
BN
blue
BU
green
GN
violet
VT
grey
GY
Multi-drive operation:
KS 15
and locking drives
Confi guration with
M-COM
Opening drive as
Master / Slave
Only with factory programming or
customer programming with UniPC USB interface.
WH
:
is used for communication, with synchronized multi-drive operation. Drives does not work, if the cable
WH
is not connected.
Optional:
1 to 4 drives and max. 2 locking drives are possible.
+
+
-
-
junction box
site-supplied
Polarity reversal
+
+
-
-
Junction box site-supplied
Master
Slave
Polarity reversal
The running direction of the 24V-drive may be changed
by interchanging (polarity reversal) the wires
„BN -
(brown)“
-
„BU - (blue)“
.
Connection assignment
BN
+
-
BU
-
+
BN
VT
WH
GN
BU
WH is used for communication,
with synchronized multi-drive
operation
Version Z:
contact max. 24V, 500 mA
(min. 10mA)
No voltage on white wires (
WH
) - drives can
be damaged!
07
KS 15
AK