Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
Mechanical position indicator
(option)
Blinker transmitter (standard for SA, option for SAR)
Running indication
Voltages: 110 – 220 V AC, 220 – 240 V AC or 400 V AC
Power depending on the size 12.5 – 25 W
Motor heater (option)
Manual drive for setting and emergency operation, handwheel does not rotate during electrical
operation.
Option: Handwheel lockable
Manual operation
AUMA plug/socket connector with screw-type connection
Connection to controls
Standard: B1 according to EN ISO 5210
Options:
A, B2, B3, B4 according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special output drive types: AF, B3D, ED, DD, IB1, IB3
A with stem lubrication
Valve attachment
For nominal voltage and 20 °C ambient temperature and an average load with running torque or modulating torque according to sepa-
rate technical data. The type of duty must not be exceeded.
1)
Technical data for limit and torque switches
2 x 10
6
starts
Mechanical lifetime
Silver plated contacts:
30 V AC/DC
U min.
250 V AC/DC
U max.
20 mA
I min.
5 A at 250 V (resistive load)
3 A at 250 V (inductive load, cos phi = 0.6)
I max. AC current
0.4 A at 250 V (resistive load)
0.03 A at 250 V (inductive load, L/R = 3 µs)
7 A at 30 V (resistive load)
5 A at 30 V (inductive load, L/R = 3 µs)
I max. DC current
Gold plated contacts:
5 V
U min.
30 V
U max.
4 mA
I min.
400 mA
I max.
Technical data for blinker transmitter
10
7
starts
Mechanical lifetime
Silver plated contacts:
10 V AC/DC
U min.
250 V AC/DC
U max.
3 A at 250 V (resistive load)
2 A at 250 V (inductive load, cos phi
≈
0.8)
I max. AC current
0.25 A at 250 V (resistive load)
I max. DC current
58
SAExC 07.1 – SAExC 16.1/SARExC 07.1 – SARExC 16.1
Technical data
AMExB 01.1