Persons who have not read and understood the operating instructions 
should not use the pressure filter! 
 

This device is not intended for use by persons or children with physical, sensory 
or intellectual impairments, or if lacking in experience and or know-how, unless 
they are under supervision or have been trained in the use of the device by a 
person responsible for their safety. 
Children should be supervised to ensure that they do not play with the device. 

 
Intended use 

The VarioPress Pro is a pressure filter with built-in UV-C for mechanical and 
partial biological filtration of the pond water of standard ponds with temperatures 
from +4 º C to 35 º C. The pressure filter is designed for private use for cleaning 
garden ponds with or without fish (no koi). A pump is necessary for the operation 
of the pressure filter, which pumps the pond water through the pressure filter. 

 
Scope of application: 

If there are people in the water, the pressure filter is not allowed to operate! 
(disconnect pressure filter from the power supply.) 

It may not be used in or near swimming lakes or swimming pools! 
 
Safety instructions

 

 

Attention! UV-C radiation is harmful to eyes and skin! 

 

Only use the UV-C lamp of the pressure filter in the closed device.

 

The operation of the lamp is easy to observe through the 
transparent inspection glass.

 

 

Warning!

 This pressure filter may only be used in ponds if the electrical 

system meets relevant statutory requirements.  

o

 

If in doubt, consult a qualified installer. 

 

The pressure filter may only be connected to a system with a 

 

ground-fault circuit interrupter (30 mA) and earthed power 
outlet.

 

 

The power supply and current type must match the data on the model 
tag or as shown in the table on page 2. 

 

The pressure filter must be set up at least 2 meters from the waterfront. 
(Refer to illustration 1.) 

 

Place the power outlet in a moisture-free area, at least 2m from the 
water's edge (Refer to illustration 1.) 

 

Check the power cord, plug and pressure filter for damage before using 
the pressure filter. 

 

Important:

 do not use if the cord, plug or pressure filter are damaged. 

Go back to the dealer to assess the damage. 

 

Do not move or hang the pressure filter by the power cord. 

 

Keep the plug dry. To prevent water from running from the cord to the 
plug, suspend the cord in a U-shape (Refer to illustration 9.) 

 

When working on the pressure filter, always disconnect the pressure 
filter and take off the pump outlet connected to the pressure filter, so 
that the power supply to the pressure filter and pump is disconnected. 

 

The UV-C lamp of the pressure filter may only be switched on if it is 
completely filled with water and if there is an adequate flow of water 
through the pressure filter.  
 

 

 

 

English 

Summary of Contents for VarioPress Pro 24000

Page 1: ...ilter Pressure filter VarioPress Pro G e b r u i k s a a n w i j z i n g I n s t r u c t i o n s d u t i l i s a t i o n B e d i e n u n g s a n l e i t u n g O p e r a t i o n i n s t r u c t i o n s Zuiveren Purification Klären Purifying www auga nl ...

Page 2: ...dingen figure Bilder Pictures 3 Gebruiksaanwijzing NL 8 Instructions d utilisation F 16 Bedienungsanleitung D 24 Operation instructions GB 33 Garantiecertificaat Certificat de garantie Garantie Zertifikat 40 Warranty certificate Specificaties Spécifications Technische Daten Specifications Type Q max H max Volt Hz UV c Art nr VarioPress Pro l h m W in m in inch Ø in mm Ø in mm Art n 24000 12000 5 2...

Page 3: ...ress Pro 60000 2 3 Symbolen Symboles Symbole Symbols Aanvoerslang buis Retourslang buis Vuilwaterslang buis Tuyau d ali e tatio Tuyau de retour Tuyau des eaux usées Zulaufschlauch Rohr Rücklaufschaluch Rohr Abwasserschlauch Rohr Supply hose pipe Return hose pipe Waste water hose pipe 4 ...

Page 4: ...www auga nl 4 Afbeeldingen Figure Bilder Pictures 5 6 VarioPress Pro 24000 40000 VarioPress Pro 60000 7 8 9 ...

Page 5: ...www auga nl 5 Afbeeldingen Figure Bilder Pictures 12 13 10 11 ...

Page 6: ...www auga nl 6 Afbeeldingen Figure Bilder Pictures 14 VarioPress Pro 24000 40000 ...

Page 7: ...www auga nl 7 Afbeeldingen Figure Bilder Pictures 15 VarioPress Pro 60000 ...

Page 8: ...ation of the lamp is easy to observe through the transparent inspection glass Warning This pressure filter may only be used in ponds if the electrical system meets relevant statutory requirements o If in doubt consult a qualified installer The pressure filter may only be connected to a system with a ground fault circuit interrupter 30 mA and earthed power outlet The power supply and current type m...

Page 9: ...l and biological filtration of the water in the garden pond A Inlet connect the supply hose or PVC pipe here that is connected to the outlet side of the pump The maximum pump pressure should be 6m 0 6 bar B Vortex floating particles and deposits are deposited by centrifugal and gravitational forces C Mechanical filtration dirt particles are trapped on the filter foam as the water passes through th...

Page 10: ...ss Pro 24000 and 40000 the pressure filter can be buried up to about 2 3 to just below the clamp ring Connecting the hose or PVC pipe choose a large hose or PVC pipe to prevent flow resistance Choosing a hose a Mount the 3 taps with hose connection and seal fig 12 to the connections A F and G of the pressure filter Saw the hose fitting to the correct hose diameter prior to mounting Use hose clamps...

Page 11: ...ages 3 4 6 and 7 To guarantee a long life and trouble free operation of the filter we recommend regular maintenance and cleaning Follow the safety instructions Pressure filter maintenance strongly depends on the level of water contamination Cleaning the filter foam The foam filter should be cleaned every week or sooner if the flow decreases and the orange dirt indicator on the knob H indicates tha...

Page 12: ...rod holder 25 are properly mounted and mount the plate 26 and screw 27 Place the UV C pipe cap 11 back on the UV C pipe and fix it by turning the UV C pipe cap 11 in a clockwise direction Take the basket with bio balls 12 14 from the tank 17 and rinse it with clean pipe or pond water Also clean the tank 17 and o ring 16 with clean pipe or pond water Place the basket with bio balls 12 14 back into ...

Page 13: ...he quartz glass 6 from the UV C cap 1 7 Inspect the quartz glass 6 for any cracks or damage if necessary replace the quartz glass 6 8 Inspect the red seal 5 of the quartz glass clean and replace the red seal 5 if there are any signs of damage 9 If the UV C lamp 4 needs to be replaced remove it from the globe fitting and replace with a new lamp Use the appropriate type of UV C lamp as indicated on ...

Page 14: ...r is covered by a 24 month warranty from the date of purchase Please keep the receipt for future reference Within the period specified repair or replacement of damage caused as a result of manufacturing and or material defect will be free of charge UV C lamp quartz glass tube filter materials normal wear and tear dry running scale lack of maintenance freezing improper repairs and damage caused by ...

Page 15: ...amen met dit garantiebewijs Ne pas oublier de garder votre facture d achat avec ce certificat de garantie ensemble Vergessen Sie nicht Ihren Kaufbeleg mit diesem Garantieschein zusammen zu halten Don t forget to keep your purchase invoice with this guarantee certificate together N o 9 7 2 6 0 1 5 0 4 2 0 1 6 Garantiecertificaat Certificat de garantie Garantie Zertifikat Guarantee certificate Auga ...

Reviews: