background image

9

Connection of two PBX systems via one analog Port each 

Which Advantages do the Connection with the Auerswald Box have?

The Auerswald Box may be used to connect two PBX systems (e.g. of two houses, two companies) with
a limited distance in such a manner that free internal calls between these two PBX systems are possible. 

Which Requirements have to be fulfilled?

- Two PBX systems with one free internal analog port each

Connection and Start of Operation of the Auerswald Box

Connect the Auerswald Box to the other devices as shown in the picture.

Configure an internal telephone number (e.g. 34) in the PBX for the analog port of the Auerswald Box
labeled with „PBX/Tk-Anlage“ – if this has not been done yet. You need this telephone number to call
the Auerswald Box for configuration settings or to make calls.

Configure an internal telephone number (e.g. 33) in the PBX for the analog port of the Auerswald Box
labeled with „ATA“ – if this has not been done yet. You need this telephone number to call the Auerswald
Box to make calls.

On both extensions do not configure any external telephone number (external call distribution).

For the connection of two PBX systems no settings are necessary in the Auerswald Box. If the Auerswald
Box does not contain the default factory settings concerning call acception (immediate) and destination
number (empty), you can reset it as described in the chapter “Reset to Default Factory Settings” on
page11.

Consult the corresponding manuals of the other devices during installation.

The range of Auerswald Box and PBX may be up to 600 m depending on the type of PBX and the cable
used.

The Auerswald Box has not been certified as an analog public exchange line port for PBX systems.

Start Calls to the other PBX via Auerswald Box

To start a call the Auerswald Box is called by one internal telephone of the PBX via the corresponding
internal telephone number. As soon as the Auerswald Box establishes the connection to the other PBX
(dial tone), the requested internal telephone number of this PBX can be dialed by DTMF.

to one extension of each   
PBX  

 
 

 

into the jack  
labeled with „ATA“

into the jack  

                 labeled with „PBX/Tk-Anlage“ 

PBX

PBX 

N

N

pick up the 

receiver of any 
available inter-

nal telephone 

dial the telephone number 

of the internal   extension 

of the Auerswald Box 

(e.g. 34)

Auerswald Box establishes 

the connection between 

both PBX systems (LED 

glows)

dial tone 

from the 

other PBX 

dial destina-

tion number 

with DTMF 

PBX calls the desti-

nation subscriber 

Summary of Contents for Box

Page 1: ...Default Factory Settings 11 Drilling Template 12 F Features 2 G General Advice 10 I Important Information Call Through 8 Internet Telephony 6 two PBX systems 10 Internet Calls 3 Internet Telephony 2 L LED Signalization 11 M Maximum Call Duration 10 O Operation Call Through 7 Internet Telephony 3 two PBX systems 9 R Requirements Call Through 7 Internet Telephony 3 S Scope of Delivery 11 T Technical...

Page 2: ...og or ISDN cable connection The digital voice data is sent as IP packets from one telephone to the other partner This works like the transfer of a homepage from the Internet There are already numerous providers who do not only allow to make outgoing calls but also offer an individual telephone number for each customer With this telephone number you can also telephone into the fixed network and sta...

Page 3: ... or SIP provider Outgoing Internet Calls with the Auerswald Box To start a call via the Internet the Auerswald Box can be called by each internal subscriber of the PBX As soon as the Auerswald Box establishes the connection to the ATA dial tone the telephone number to be dialed in the Internet can be entered by DTMF Incoming Internet Calls with the Auerswald Box There are different operation modes...

Page 4: ...h the ATA If the caller does nothing the PBX will dial a pre configured internal or external telephone number Like in the operation mode C the PBX can be used for dialing through to an external telephone number in the fixed network or to the mobile telephone network The advantage over operation mode C is The caller will always be connected even if he has no knowledge about the internal telephone n...

Page 5: ...ary in the Auerswald Box If the Auerswald Box does not have the default factory settings concerning call acception immediate and destination number empty you can reset it as described in the chapter Reset to Default Factory Settings on page 11 N 1 N press the programming key on the Auerswald Box for at least 3 seconds until the LED nearby flashes pick up the receiver of any available inter nal tel...

Page 6: ...rmits a maximum call duration of 60 minutes How it can be changed is described in the chapter Configure the maximum Call Duration on page 10 Configure a number restriction e g 0900 for the internal extension of the Auerswald Box if supported by the PBX see manual of the PBX to prevent the dialing of these telephone numbers Configure if supported by the PBX LCR Least Cost Routing for the internal e...

Page 7: ...se all functions that are possible on this extension Therefore assign the authorizations correspondingly Do not configure any external telephone number for this extension For Call Through there are no settings necessary in the Auerswald Box If the Auerswald Box does not have the default factory settings anymore concerning call acception immediate and destination number empty you can reset it as de...

Page 8: ...t Routing for the internal extension of the Auerswald Box to save money see manual of the PBX Each internal subscriber can start outgoing external calls with the Auerswald Box In this case a restriction by authorizations or number restrictions e g 0900 0190 0180 is not possible e Attention Please check if the PBX generates a busy tone on the port connected to the jack PBX Tk Anlage on call complet...

Page 9: ...n of two PBX systems no settings are necessary in the Auerswald Box If the Auerswald Box does not contain the default factory settings concerning call acception immediate and destination number empty you can reset it as described in the chapter Reset to Default Factory Settings on page11 Consult the corresponding manuals of the other devices during installation The range of Auerswald Box and PBX m...

Page 10: ... access number e g 0 the Auerswald Box cannot be reached for the next 2 minutes In the default factory settings the Auerswald Box only allows a maximum call duration of 60 minutes for incoming and outgoing calls due to safety reasons How to change it or to disable the restriction is described in the following in the chapter Configure the maximum Call Duration Configure the maximum Call Duration In...

Page 11: ...e blue semitransparent 2 pieces Dimensions 얒 95 x 33 mm Weight app 90 g Safety CE Temperature 0 to 40 C of environment Layout of Western modular jacks Scope of Delivery 앫 1 device Auerswald Box 앫 2 connection cables RJ 11 on RJ 11 앫 User manual 앫 Guarantee flyer 앫 Mounting Material 2 screws and 2 dowels Wall Mounting The device is also made for wall mounting Drill two wholes with a diameter of 6 m...

Page 12: ...12 Drilling Template ...

Reviews: