POWERING UP THE M63
When phantom power (48V) is supplied to the M63, the LEDs will blink red and green
to indicate that the unit is receiving power. Following the power-up sequence, the
LEDs will behave according to the setting specified by the DIP switch configuration.
*When connecting to a DSP, DIP switch 3 is always set to the left position.
SWITCH
USE
SETTING
SW1
Determines whether LEDs will be used to
indicate both active and muted states
RIGHT:
Active and mute status with alternate color LEDs
LEFT:
Only active state will be indicated by LEDs
SW2
Determines whether red or green
LED indicates active state
RIGHT:
Active is green
LEFT:
Active is red
SW3*
Sets microphone to local (internal logic)
mode or external DSP logic control
RIGHT:
Local control
LEFT:
External DSP logic
SW4
Sets microphone’s initial state to ON or MUTE
when phantom power is supplied (SW4 is
disabled when SW3 is in external DSP)
RIGHT:
Press to activate (muted on power-up)
LEFT:
Press to mute (active on power-up)
SW5
Determines whether mic is in
toggle or momentary mode
RIGHT:
Toggle between active and mute status
LEFT:
Momentary. Press and hold button to maintain
either active or muted state (as specified by SW4)
SW6
Not assigned
SW1 LEFT:
LEDs for active only
SW1 RIGHT:
LEDs for active and muted
SW2 LEFT:
Active LED color red
SW2 RIGHT:
Active LED color green
SW3 LEFT:
External DSP logic
SW3 RIGHT:
Internal local logic
SW4 LEFT:
Mic on at power up
SW4 RIGHT:
Mic off at power up
SW5 LEFT:
Mic switch momentary
SW5 RIGHT:
Mic switch toggle
SW6 LEFT
:
Not assigned
SW6 RIGHT
:
Not assigned
DIP SWITCH SETTINGS
DIP switches can be accessed by
removing the grille (see Mounting for
removal instructions). To locate the DIP
switches, refer to the illustration at right.
DIP SWITCHES
SW 6
PUS
H
L