CPA240 Configurable Power Amplifier
Page 25 of 35
21031 CPA240 manual V1.31.doc
6 Mains Voltage Selection
The CPA240 amplifier is provided with a mains voltage selector.
This selector allows the amplifier to produce optimum power output without the risk of over
temperature shutdown due to excessive heat dissipation.
Note: It is critical that the mains voltage selector is adjusted to the correct setting.
Front of Amplifier
Main Voltage
Selector V.a.c
24
0
23
0
22
0
Access hole in
side of chassis
6.1 Setting Mains Voltage Selector
•
Using a DVM measure the incoming mains voltage to the amplifier (or equipment rack)
•
Set the amplifier voltage selector to nearest resulting position see table
•
Repeat setting for all other amplifiers in the equipment rack
Voltage
measured
Voltage selector setting
208 - 229
220
230 – 239
230
240 – 253
240
If the voltage selector is incorrectly set the amplifier may shutdown due to excessive
heat dissipation or even be permanently damaged. Therefore it is crucial that the selector
is set correctly.