ADJUST THE INTERIOR ZONE:

Use 

CAUTION when making adjustments to this sensor.  The sensitivity adjustment has a maximum

rotation of approximately 260 degrees. 

DO NOT OVERTURN THIS ADJUSTMENT SCREW.

Set the dip switches as shown in figure 2 to adjust the interior zone. The security system must be armed
during the adjustment procedure, however the alarm system will not trigger when the switches are set as
shown.
Turn the  INT. adjustment potentiometer half way up, open both left and right front windows.  Exit the
vehicle and wave your arm inside the right and left front windows. The sensor will emit chirps when you've
entered it's field. Adjust the sensitivity up or down until the desired result is achieved.

OPERATING WITH LIMITED EXTERIOR ZONE:

Set the dip switches as shown in FIGURE 3 to operate with limited exterior zone operation. In this mode
the sensor will trigger the alarm after four detections of the exterior zone violation within 15 seconds.
When the unit detects a third exterior zone violation, it will emit a series of warning chirps. If one additional
violation occurs, the alarm will trigger.

OPERATING WITH FULL EXTERIOR AND INTERIOR PROTECTION:

To operate with full dual zone protection, set the dip switches as shown in FIGURE 4 .  In this mode, when
arming the system, the sensor will not trigger for 5 seconds. After the 5 second stabilizing period, if the
exterior zone is violated, the siren will emit a series of warning chirps. If the interior zone is violated, the
alarm will trigger.
Note : During pre-detect, the green L.E.D. will turn on for 3 seconds.  During full trigger, the red L.E.D. will

turn on briefly.

Note : Interior zone must always be set lower than exterior zone for proper operation.