34
Error code 5:
Cause:
Repeated transmission errors have occurred between the CONDUCTOR and the DSP / DSP ampli-
fier’s ACO platform.
Solution:
Check the cable for damage and tight fit of the plug connector.
Error code 8:
Cause:
An unknown error has occurred.
Solution:
Check all plug connections and use the latest version of the DSP PC-Tool.
Problem: CONDUCTOR does not turn on
Possible cause: Faulty plug connection.
Solution:
Check the tight fit of the plug connector.
Problem: LED lighting off
Possible cause: The “LED Dimming” setting is configured to “LEDs off”, which will turn off the illumination after 8 sec
-
onds of inactivity. If this is not the case, check the wiring.
Solution:
Enable the LED feedback rendition as described on page 29 in point 4.1.5 “LED Dimming”.
Problem: No sound
Possible cause: Volume set too low; mute activated; incorrect input source.
Solution:
Check volume level of Volumes 1 - 4 and whether they have been activated in the DSP PC-Tool;
disable mute (muting is signalled by a single rotating LED / demuting: The knob must be pressed for
a long time or turned when the volume menu is selected); change input source.
Problem: No connection with compatible device possible
Possible cause: Transmission problem to the DSP; incompatible software versions.
Solution:
Check the tight fit of the CONDUCTOR plug connector; update the CONDUCTOR and ACO software
with the current DSP PC-Tool.
6. Troubleshooting