Audionet AMP VII User Manual Download Page 21

21

 

 

Note 

· 

In case of thermal overload the AMP VII will always switch off in-
dependently from the display setting. 

· 

The temperature display mode gives the user a clue about the thermal 
load of the AMP VII. It depends on the placement, air flow and cool-
ing, surrounding temperature and the number of installed modules in 
the AMP VII. Nevertheless, the full musical performance is achievd 
even if the display reports 

Temperature Cool

 

 

8.3  Set Input 

The user can select the input for all modules simultaneously or individu-
ally.  First,  navigate  to  menu  item 

Select  Module

  and  enter  the  sub 

menu 

SET INPUT FOR

 with a long keystroke on the 

power

 key. 

Now  use  short  keystrokes  to  select  the  module  whose  input  you  would 
like to configure: 

all Amp Modules 

Use  this  setting  if  you  would  like  to  configure 
the  input  for  all  modules  simultaneously.  All 
modules will be set to the same input after the 
following configuration. 

Amp Module No. x 

Select  the  module  whose  input  you  would  like 
to configure individually. The input settings of 
all other modules are not affected after the fol-
lowing configuration. 

 

Acknowledge  the  module  selection  with  a  long  keystroke  of  the 

power

 

key on the front panel. The AMP VII enters the sub menu 

Set Input

 

Now select the desired input: 

Line (Cinch) 

Select this option if you connected your re amplifier 
to the Cinch input of the module. 

Balanced (XLR) 

Select  this  option  if  you  connected  your  pre  ampli-
fier to the balanced (XLR) input of the module. 

 

do not change 

Select this option if you would like to exit the menu 
without any change. This option is only available if 
you selected 

all Amp Modules

 before and not all 

modules are set to the same input. 

 

 

 

 

Summary of Contents for AMP VII

Page 1: ...1 Modular Multichannel Power Amplifier User s Manual...

Page 2: ...2...

Page 3: ...mains plug 10 5 Inputs and outputs 11 5 1 Inputs 11 5 2 Speaker terminals 11 5 3 Audionet Link 12 6 Operating 13 6 1 Powering up 13 6 2 Switching on off 13 6 3 Mains phase detection 14 6 4 Using Audi...

Page 4: ...4 9 Technical information 24 9 1 Design 24 9 2 Circuitry 24 9 3 Power supply 24 9 4 Handling 24 10 Security advice 25 11 Technical data 26...

Page 5: ...not only the pure power and rock solid stability impresses the lis tener The AMP VII unites them with excessive richness of information and subtle details as well as perfect immaculateness of sound F...

Page 6: ...currently reading two standard mains cords 1 2 Transport Important Please transport the AMP VII only in the included package Always use the plastic bag to prevent scratches on the housing Please allo...

Page 7: ...7 2 Overview control elements 2 1 Frontpanel Note The mains switch is located at the front right side on the bottom of the unit Display power AMP VII Multichannel poweramplifier power key Mains switch...

Page 8: ...inch input channel 4 9 Balanced XLR input channel 5 10 Cinch input channel 5 11 Balanced XLR input channel 6 12 Cinch input channel 6 13 Balanced XLR input channel 7 14 Cinch input channel 7 15 Speake...

Page 9: ...the microprocessor controlled fan units on the bottom side of the AMP VII are able to intake cool air without any obstruction Particularly avoid placing the unit onto soft surfaces like furry carpets...

Page 10: ...e like vacations or if massive trouble on the mains power is to be expected you should switch off the AMP VII To disconnect the unit completely from mains pull both mains plugs Tipp Using high quality...

Page 11: ...es are in absolute best conditions Broken shields or short cut loudspeaker cables could damage speakers and or amplifiers 5 1 Inputs At first connect your pre amplifier to inputs 1 to 14 depending on...

Page 12: ...r tools tightening the terminal screws Tip If your speakers support bi wiring use two separate cables to connect each speaker to the AMP VII Impulse response and spatiality my improve significantly No...

Page 13: ...goes dark Important Never pull the mains cord s while the AMP VII is switched on Before you operate the mains switch on the bottom side or pull the mains plug power down the unit to stand by mode fir...

Page 14: ...ront panel the follow ing message appears in the display in case mains input 23 has the wrong polarization Att Mainsphase No 1 Incorrect or in case mains input 25 has the wrong polarization Att Mainsp...

Page 15: ...he AMP VII starts up automatically to normal operating mode and does not stay in stand by mode right after the unit is connected to mains power e g by operating the mains switch on the bottom side Use...

Page 16: ...or longer than 12 seconds Note While the countdown is running the display shows the remaining time until automatic start up WARM UP IN 02 hours 43 min If the display saver is active the display shows...

Page 17: ...tive speaker Overheating ventilation slots covered High Freq defective pre amplifier DC Voltage exceeding DC level at the output defective pre amplifier or source unit Power Failure temporary breakdow...

Page 18: ...ion with short keystrokes To leave a menu item hold down the power key longer than 2 seconds or simply wait longer than 12 seconds If you would like to change more settings please re enter the setup m...

Page 19: ...ange1 No change2 Line Cinch Select Cinch input2 Balanced XLR Selectbalanced XLR input2 Amp Module No 1 Line Cinch Select Cinch input3 Balanced XLR Selectbalanced XLR input3 Amp Module No 7 Set AutoSta...

Page 20: ...aver is active the display shows depending on the selected display mode Set Display either Active or the temperature of the AMP VII in the form of Temp Cool Ok High The display brightness is automatic...

Page 21: ...p Modules Use this setting if you would like to configure the input for all modules simultaneously All modules will be set to the same input after the following configuration Amp Module No x Select th...

Page 22: ...To activate the AMP VII use the power key on the front panel or the Audionet Link interface active The AutoStart function is active As soon as the AMP VII is connected to mains power the unit starts u...

Page 23: ...urnin effect see section Set Dim Level on page 20 8 6 Overview factory defaults Option Einstellung SET DIM LEVEL 50 SET DISPLAY Standard SET INPUT Line Cinch SET AUTOSTART disabled SET OFF TEXT dot No...

Page 24: ...r than 1 GHz Double boot strapping decouples the input from the power stage The power stage consists of four Power MOSFETs A complex correction circuit locally compensates distortion in real time 9 3...

Page 25: ...onment Do not cover the unit Do not open the unit Unauthorised opening will void warranty Do not short circuit the outputs During connecting or removing loudspeakers and or the pre amplifier your AMP...

Page 26: ...optical Mains 2 x 230 V 50 60 Hz Power consumption 5 Watts Stand by 1200 Watts typ 3500 Watts max Dimensions Width 430 mm Height 196 mm Depth 430 mm Weight 58 kg Finish Front brushed aluminium 10 mm b...

Page 27: ...27 audionet is a trademark of Idektron GmbH Co KG Engineered and produced by Idektron GmbH Co KG Herner Str 299 Geb ude 6 44809 Bochum Germany www audionet de contact audionet de...

Reviews: