ARCHITECT
Model 960
Model 961
Installer’s Guide
™
27
Appendix
The commands are broken into two groups:
Controls
and
Inquiries
. The
Controls
issue instructions to the Model 961 for
power control and channel muting; the
Inquires
return the status
of amplifier channels, AC line voltage, the amplifier temperature,
and the failure data log.
Control Commands
P0
(zero not ‘O’)
Main Power On
P1
Main Power Off
M1
Mute channel 1-2
M2
Mute channel 3-4
M3
Mute channel 5-6
M4
Mute channel 7-8
M5
Mute channel 9-10
M6
Mute channel 11-12
M7
Mute channel 13-14
M8
Mute channel 15-16
MA Mute all channels
U1
Unmute channel 1-2
U2
Unmute channel 3-4
U3
Unmute channel 5-6
U4
Unmute channel 7-8
U5
Unmute channel 9-10
U6
Unmute channel 11-12
U7
Unmute channel 13-14
U8
Unmute channel 15-16
UA
Unmute all channels
Inquiry Commands
M?
Binary string showing
all zones mute
status
0 = Mute
1 = Active (unmuted)
(i.e. ‘00100000’ –
zone 3 is unmuted)
S?
Protection status
(zone 1-8 and
Amp)
T?
Temperature
(zone 1-8)
P?
Main power status –
0=off, 1=on
V?
AC Line voltage –
Decimal numeric
value
L?
Protection data log
(comma delimited
text, 10 lines)
Summary of Contents for 960 961
Page 4: ...The Architect Model 960 Model 961...
Page 7: ...ARCHITECT Model 960 Model 961 Installer s Guide...
Page 14: ......
Page 15: ...ARCHITECT Model 960 Model 961 Installer s Guide...
Page 16: ......
Page 24: ......
Page 25: ...ARCHITECT Model 960 Model 961 Installer s Guide...
Page 34: ......