background image

ARCHITECT

Model 960
Model 961

Installer’s Guide

Installation:

The Long Version

9

POWER

Under normal operating conditions, the Architect 900 Series

can draw up to 1600 watts of AC power. Don’t plug it into a
switched outlet on your system unless you are certain that it can
handle the power rating. Also, please don’t cut off the ground pin
on the power connector. It is an important safety feature. If you
need to plug it into a two prong outlet, use a ground adapter (and
connect the ground on it). If you have a ground noise problem, try
the ground lift switch on the rear panel.

REMOTE POWER CONTROL

The Architect has several means of power control:

1) Main AC Power switch

- This is the master control and

must be turned ON for the Architect to function. When the main
power switch is on, the blue Power LED on the front panel lights
up. Normally the only time that you would need to turn the AC
power switch off is when the system is going to be unused for an
extended period.

2) Remote 12 volt Power Trigger 

- This removable 3-pin

remote connector on the rear panel allows simple interfacing with
external control systems. It accepts either a contact closure or
ex12 volts DC. (see diagram) The two-color Protection
LED on the front panel illuminates Blue to show that the remote
power control is active.

3) Ethernet Control 

 

If you have the Architect Model 961

with the Ethernet control port you have remote control over the
amplifiers power from almost anywhere in the world via the
Internet. This is also very useful on a more local sense for inte-
grating the amplifier with a home automation system via Ethernet.

4) Signal Sensing 

-  Another level of amplifier control is the

Signal-Sense circuitry. This provides individual channel muting
control. When active, it senses that an audio signal is present on
the RCA inputs then enables the power and unmutes that zone.
The zone status LEDs on the front panel light up Blue when a
signal is present.

In some installations it may be desirable to defeat the signal-

sense control and leave all zones active regardless of the audio
input. To defeat the signal-sense, press in the Signal-Sense Defeat
button on the rear panel

Installation Hint: If your

installation doesn’t require

this remote power turn-on, you

must put a short piece
of wire between the
+12 V output and
the Trigger In
pins.

Warning - Always

connect the safety
earth ground. If

you have an AC hum problem, use
the ground lift switch

Note: Do not use the 12 volt
power trigger if you are using the
ethernet control. The power turn
on is controlled by the ethernet

Summary of Contents for 960 961

Page 1: ...mplifier Speaker Optimizer Professional Installer s Consciousness Guide 22410 70th Avenue West Mountlake Terrace WA 98043 USA 425 775 8461 Fax 425 778 3166 www audiocontrol com For Those Who Consider...

Page 2: ...______________________________ Date Installed _______________________________________ Serial Number ______________________________________ Ethernet MAC Address _______________________________ IP Addre...

Page 3: ...alization Controls 15 A Short Introduction To Equalizers And Acoustics 16 Audio Analysis Using Pink Noise 17 What s Inside 18 The Truth About Bass and The Programmable Frequency Match Filter 18 Patent...

Page 4: ...The Architect Model 960 Model 961...

Page 5: ...e professional sound division designed and sells the most popular one third octave real time analyzer in the world the SA 3050 AudioControl s passion for high quality meticulous attention to detail an...

Page 6: ...s 75Hz 250Hz 700Hz 2500Hz and 12KHz band centers were chosen to optimize in wall and 2 way bookshelf speakers at critical frequencies where adjustment is most advantageous The bandwidths or Q as our e...

Page 7: ...ARCHITECT Model 960 Model 961 Installer s Guide...

Page 8: ...two purposes First they illuminate Blue when the corresponding channel is active The second function of the status LED is to turn Red if something has caused that zone to go into protection 4 Protect...

Page 9: ...ARCHITECT Model 960 Model 961 Installer s Guide 5 A Guided Tour Of The Architecttm 900 Series more rear panel features on the next page...

Page 10: ...ul goes wrong There are no internal fuses in this amp Power Cord The Architect draws a maximum of 1600 watts at full power Make certain that it is plugged directly into the wall outlet or a power stri...

Page 11: ...unt the Architect more than 20 feet from the preamp 5 Enough speaker wire to reach all of your speakers 6 Multi zone audio controller receiver or preamplifier 7 Although you can set the speaker optimi...

Page 12: ...and make certain the home owner puts it away in a safe place Stashing the receipt away is very important in the unlikely event that your Architect ever needs servicing or well things do happen you nee...

Page 13: ...iagram The two color Protection LED on the front panel illuminates Blue to show that the remote power control is active 3 Ethernet Control If you have the Architect Model 961 with the Ethernet control...

Page 14: ......

Page 15: ...ARCHITECT Model 960 Model 961 Installer s Guide...

Page 16: ......

Page 17: ...aker runs can have significant resistance if you use a smaller wire gauge This can be a benefit if you are paralleling lots of speakers The wire itself acts as an impedance limiter since the amplifier...

Page 18: ...c begins 4 Check each speaker output zone to ensure that each one plays properly 5 With all the speaker loads turned on turn up the volume and make certain that the channel status LEDs on the Architec...

Page 19: ...ce too much midrange so these controls are candidates for being turned down slightly during your initial experimentation Definitely consider reducing 700 Hz if you are only using your extension speake...

Page 20: ...lect back sound waves bounce off walls ceilings and floors reflecting reinforcing and canceling each other as shown in the figure above Since sound is energy the way it reflects depends upon the angle...

Page 21: ...the printed page call us and we ll mail you a copy The overall point that we re trying to make is that the various rooms in your home function as gigantic mechanical equalizers boosting or cutting cer...

Page 22: ...l midrange area When the woofer is bashing around trying to reproduce unrealisti cally low bass its ability to produce midrange is compromised due to intermodulation distortion So not only don t you g...

Page 23: ...lume is turned up too high and an amplifier is pushed into clipping the resulting distortion will probably damage the tweet ers in your speakers AudioControl s exclusive LightDrive protec tion system...

Page 24: ......

Page 25: ...ARCHITECT Model 960 Model 961 Installer s Guide...

Page 26: ...assigned to it every time you dial up A network installation using Dynamic IP address requires a dedi cated device known as a DHCP Dynamic Host Control Protocol server to assign the IP addresses from...

Page 27: ...Sense circuit using switch on the rear panel All of the Channel Status LEDs should turn on If they do not call the AudioControl factory b Verify Source unit is operating c Adjust the preamp volume hig...

Page 28: ...nabling the PFM filter 6 There is no audio input signal but the Channel Status 6 LED is still Blue a Check the Signal Sense defeat switch on the rear panel If it is pressed in the Channel Status LEDs...

Page 29: ...justments to instantly compensate for main system speaker and room deficiencies In fact AudioControl was the world s first manufacturer of a SEVEN CHANNEL equalizer for home theater surround sound use...

Page 30: ...the Architect Model 961 via Telnet you need a Telnet client program in your system The factory default static IP address of the Model 961 is 192 168 0 1 and telnet is active on port 23 The default us...

Page 31: ...nnel 5 6 M4 Mute channel 7 8 M5 Mute channel 9 10 M6 Mute channel 11 12 M7 Mute channel 13 14 M8 Mute channel 15 16 MA Mute all channels U1 Unmute channel 1 2 U2 Unmute channel 3 4 U3 Unmute channel 5...

Page 32: ...at voids your warranty 5 The warranty is also void if the serial number is altered or re moved or if The Architecthas been used improperly Now that sounds like a big loophole but here is all we mean b...

Page 33: ...xplanation of the trouble you are having with The Architecttm You d be surprised how many people forget this 3 A return street address No PO Boxes please 4 A daytime phone number in case our technican...

Page 34: ......

Page 35: ...Trigger 12 VDC or Dry Contact Closure AC Power Consumption 1600 Watts all channels full power AC Main Fuse Rating 2 x 6 amp Slo Blo AC Main Operational Voltage 95 volts 130 volts Weight 48 pounds 22...

Page 36: ...080 0 22410 70th Avenue West Mountlake Terrace WA 98043 USA 425 775 8461 Fax 425 778 3166 e mail info audiocontrol com Visit us on the web at www audiocontrol com For Those Who Consider Perfection Po...

Reviews: