Version 6.6
31
September 2013
Hardware Installation Manual
6. Hardware Maintenance
6
Hardware Maintenance
The device is designed as a modular chassis and allows you to order any module as a
Field Replacement Unit (FRU). This section describes the procedures for installing or
replacing modules.
Warning:
Maintenance service of this device must be made only by qualified
service personnel in restricted access locations and connected to an
earthed power socket.
Note:
Ensure that all unoccupied module chassis slots are covered with blank panels.
This allows optimal internal airflow pressure within the chassis.
6.1
Prerequisites
Before performing any maintenance procedures, read this section.
6.1.1
Grounding the Device
Before performing any maintenance procedures, ensure that your device is properly
grounded, as described in Section
on page
6.1.2
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) due to improper handling of the device's modules and
components can cause irreversible damage to the equipment. Adhere to the following
guidelines for preventing ESD:
When handling modules, always wear a grounded ESD wrist strap or ankle strap at a
grounded work area to prevent ESD. Connect the equipment end of the strap to the
chassis ESD screw (described in the procedure below).
To prevent static electrical damage to the module, do not touch the electrical
components of the module. Instead, hold the module only on the edges where no
electrical components are located.
Ensure that the modules are securely installed in the chassis.
To attach an ESD wrist strap to the chassis:
1.
Attach the ESD wrist strap to your body (typically, the wrist) so that it is in direct
contact with your skin.
2.
Attach the other end of the wrist strap (e.g., an alligator clip) to the ESD spring screw
located on the rear panel of the chassis, as shown below.
Figure
6-1: Connecting ESD Wrist Strap to Chassis ESD Lug
Summary of Contents for Mediant 4000 E-SBC
Page 2: ......
Page 8: ...Hardware Installation Manual 8 Document LTRT 41503 Mediant 4000 E SBC Reader s Notes ...
Page 10: ...Hardware Installation Manual 10 Document LTRT 41503 Mediant 4000 E SBC Reader s Notes ...
Page 18: ...Hardware Installation Manual 18 Document LTRT 41503 Mediant 4000 E SBC Reader s Notes ...
Page 36: ...Hardware Installation Manual www audiocodes com ...