Hardware Installation Manual
12
Document #: LTRT-41503
Mediant 4000 E-SBC
Table
3-2: Front-Panel Description
Item #
Component Description
1
Fan Tray module with a schematic displayed on its front panel showing the
chassis' slot numbers. For more information on this module, see Section
on page
The figure below shows the location of the Fan Tray module, Power Supply
modules, and chassis slot numbers:
2
Power Supply module No. 2. For more information, see Section
3
Power Supply module No. 1. For more information, see Section
on page
4
Slots 1-2, shown covered with blank AMC modules for unused AMC slots.
These slots house the optional, Media Processing Module (MPM).
Note:
The MPM is a customer-ordered item.
5
Slots 3-4, covered with blank AMC modules for unused AMC slots.
Notes:
If you purchased this device in an initial release, Slots 3-4 may be
occupied by the E-SBC CPU AMC module (instead of Slots 5-6).
If this slot is occupied by the E-SBC CPU AMC module and you have
subsequently purchased the MPM, you must re-locate the E-SBC module
to Slots 5-6 instead.
6
Slot 5-6 with E-SBC CPU AMC module (hereafter referred to as
E-SBC
),
providing CPU, serial interface, and Ethernet interface functionalities. For
more information, see Section
Note:
If you purchased this device in an initial release, the E-SBC module
may be occupied in Slots 3-4 (instead of Slots 5-6).
7
Slots 7-8, covered with blank covers for unused AMC slots.
Note:
These slots are currently reserved for future use.
3.2.1
Fan Tray Module
The Fan Tray module contains six integrated fans which cool the device's internal
components. The Fan Tray module draws in air through a perforated grill on the left side of
the chassis. The incoming air passes through the entire set of modules, cooling each one,
and then exits the device through perforated vents on the right side of the chassis.
The front panel of the module provides a label showing the chassis slot assignments for
the different modules.
3.2.2
Power Supply Modules
The chassis houses up to two Power Supply modules for providing power load sharing and
AC power redundancy in case of failure of one of the Power Supply modules. Each module
provides an AC power inlet on the rear panel of the chassis for connection to an electrical
power outlet.
Summary of Contents for Mediant 4000 E-SBC
Page 2: ......
Page 8: ...Hardware Installation Manual 8 Document LTRT 41503 Mediant 4000 E SBC Reader s Notes ...
Page 10: ...Hardware Installation Manual 10 Document LTRT 41503 Mediant 4000 E SBC Reader s Notes ...
Page 18: ...Hardware Installation Manual 18 Document LTRT 41503 Mediant 4000 E SBC Reader s Notes ...
Page 36: ...Hardware Installation Manual www audiocodes com ...