5. Cabling the Device
5
Cabling the Device
This section describes how to cable the device:
Grounding the device – see Section
on page
Connecting to the LAN – see Section
on page
Connecting to a computer for serial communication – see Section
on page
Connecting to power – see Section
on page
5.1
Grounding the Device
The procedure below describes how to ground the device.
Protective Earthing
The equipment is classified as Class I according to EN-60950-1 and UL 60950-1
and must be earthed at all times (using an equipment-earthing conductor).
•
Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan."
•
Norway: "Apparatet rna tilkoples jordet stikkontakt."
•
Sweden: "Apparaten skall anslutas till jordat uttag."
To ground the device:
1.
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
earthing screw (located on the rear panel), using the supplied washer.
Figure
5-1: Grounding the Device
2.
Connect the other end of the strap to a protective earthing. This should be in
accordance with the regulations enforced in the country in which the device is
installed.