Version 7.0
111
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.20
PEM Module Alarm
PEM Module Alarm
Description
This alarm is sent in one of the following cases:
The HA (High Availability) feature is active and one of the PEM
(Power Entry Module) units is missing
PEM card is in its location and both DC wires are in.
SNMP Alarm
acPEMAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.31
Default Severity
Critical
Alarm Source
hassis#0/PemCard#<m>, where
m
is the power entry module’s (PEM)
slot number
Alarm Type
equipmentAlarm
Probable Cause
underlyingResourceUnavailable
Alarm Severity
Condition
<text>
Corrective Action
Critical
The HA (High Availability)
feature is active and one
of the PEMs (Power Entry
Modules) is missing.
PEM Module
Alarm. PEM
card is missing.
1.
Make sure the PEMs are
present and that they're
inserted correctly.
2.
If it's present and
inserted correctly yet the
alarm remains active,
send a Return
Merchandise
Authorization (RMA)
request to AudioCodes.
Cleared
PEM card is placed and
both DC wires are in.
-
-