 6.2 

Typical Application 
 
6.2.1   This system is fully compatible with Audio International’s proprietary  

RS-485 digital data bus system.  It can be configured for IR remote 
control utilizing AI’s  remote  control  unit  AI-RC1-17xxxx  and        
IFR-485. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

6.2.2   The unit can also be configured for IR remote control utilizing AI’s 

remote control unit AI-RC1-17xxxx and IFR-9A.  This following 
configuration utilizes a +5 VDC digital logic level for activation of 
infrared commands.  Connection to multiple IFR-9A units utilizing 
the +5 VDC digital logic level connection requires an external 
Schottkey diode at each IFR-9A unit.  This will prevent signal 
loading.  Contact AI for details. 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Summary of Contents for VCP-014-01-x

Page 1: ...14 04 x VCP 014 05 x 7300 Industry Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 www audiointl com Installation Operation Manual VCP 014 0x x Multi Standard Video Cassette Playe...

Page 2: ...line Drawing 523322 Rev IR VCP 014 05 x Outline Drawing Service Bulletin List Service Bulletin Subject Manual Revision Revision Date Table of Illustrations PROPRIETARY INFORMATION NOTICE Despite any o...

Page 3: ...l Equipment 4 5 0 Technical Specifications 4 6 0 Application 5 II Installation 7 1 0 Prior to Installation 7 2 0 Unpacking and Inspection 7 3 0 Cautions Warnings 8 4 0 Wiring Requirements 9 5 0 Physic...

Page 4: ...number designates the type of connector utilized 1 Positronic and 2 D Subminiature Also included are mechanical and electrical characteristics of the unit 2 0 Purpose of the Equipment 2 1 The VCP 014...

Page 5: ...g requirements q Easy to mount and connect q AI proprietary RS 485 data bus compatible q Compact lightweight package 4 0 Optional Equipment The VCP 014 0x x can be optionally controlled by infrared re...

Page 6: ...lting to an input video source when the playback options are not in use 6 1 2 The VCP 014 02 x has the same features and capability as the VCP 014 01 x However the VCP 014 02 x has a chamfered back ed...

Page 7: ...utilizing AI s remote control unit AI RC1 17xxxx and IFR 485 6 2 2 The unit can also be configured for IR remote control utilizing AI s remote control unit AI RC1 17xxxx and IFR 9A This following con...

Page 8: ...all other audio visual modules is necessary Some of the items to be considered include Space Available power supply Environmental conditions temperature humidity etc Length of cable runs Location of...

Page 9: ...orage or reshipment if necessary 3 0 Cautions Warnings 3 1 It is important to do a pin to pin power and ground check on all connectors Ensure that power and ground are applied only where specified Dam...

Page 10: ...wires shall be 22 AWG MINIMUM Power ground wires shall be grounded within twelve inches of the unit All wires must be in accordance with the standard military specification of MIL W 22759 or equivalen...

Page 11: ...uration requires no infrared strap pins to be connected Each type of AI source equipment can be configured to accept one 1 of four 4 different sets of infrared codes To change the code settings connec...

Page 12: ...o player Use the VCP 014 0x x front panel controls or the handheld remote control unit to select PLAY Verify a picture can be viewed on the appropriate monitor and that the audio can be heard through...

Page 13: ...PLAY when tape is engaged No power Circuit breaker has opened Reset circuit breaker Black White picture only SECAM formatted tape Replace tape with other than SECAM formatted tape Poor video quality P...

Page 14: ...014 0x x Installation Operation Manual Document 540097 Rev B 09 2001 Page 13 of 21 9 0 Reference Drawings The following diagrams show the unit dimensions and connector locations for the VCP 014 01 x V...

Page 15: ...Audio International Inc VCP 014 0x x Installation Operation Manual Document 540097 Rev B 09 2001 Page 14 of 21...

Page 16: ...dio International Inc VCP 014 0x x Installation Operation Manual Document 540097 Rev B 09 2001 Page 15 of 21 The following diagrams show the unit dimensions and connector locations for the VCP 014 04...

Page 17: ...Audio International Inc VCP 014 0x x Installation Operation Manual Document 540097 Rev B 09 2001 Page 16 of 21...

Page 18: ...dio International Inc VCP 014 0x x Installation Operation Manual Document 540097 Rev B 09 2001 Page 17 of 21 The following diagrams show the unit dimensions and connector locations for the VCP 014 05...

Page 19: ...Audio International Inc VCP 014 0x x Installation Operation Manual Document 540097 Rev B 09 2001 Page 18 of 21...

Page 20: ...sette tape is inserted into the tape slot the unit will automatically turn ON Automatic Playback When a video cassette without an erasure prevention tab is inserted playback begins automatically If po...

Page 21: ...tape playback Pause Button Press the PAUSE button to temporarily stop the video cassette tape during playback Rewind Button Press the REW rewind button to rewind the tape or to start a reverse visual...

Page 22: ...t and partially extend from the cassette slot for removal To activate a picture search momentarily press FF or REW during playback mode The tape will run at approximately five 5 times the normal speed...