6.0  operatIng tHe MatrIX swItcHer

The HMX-244 is a matrix switcher capable of routing 

audio/video signals from any of four sources to any of four 

displays. The matrix may be operated by the front panel 

controls, an IR remote control, or by RS-232 through a 

computer or other third party controller. 

The HMX-244 begins to operate as soon as power is 

turned on, handshaking with sources and displays. Unused 

ports do not operate

6.1  Front panel controls

Repeatedly press the SOURCE button in the appropriate 

zone until the desired source (1, 2, 3, or 4) is selected. 
•  Lights (1-4) indicate the source that is currently selected 

to the zone output.

•  If a source is not powered on, the HMX-244 skips to the 

next available source.

•  The Power light indicates that the unit is receiving 

power. 

6.2  Ir reMote controls

The HMX-244 includes a main remote control that can be 

used at the head end matrix location. It controls sources for 

all four zones. Each row of buttons represents a zone. To 

disconnect all sources from a zone, press OFF.

Auto Mode

 may be used to avoid any TV showing a blank 

screen. It automatically searches for a source input with 

active video signal beginning with input 1. If no signal is 

present, it searches input 2, 3, and 4. Override Auto Mode 

in any zone by pressing one of the other source buttons.

Each 1380R Cat 5 zone receiver includes a zone IR 

remote control. It controls only the zone output where the 

1380R is located. The IR ports are only active when an 

HDMI signal is present on both the source and respective 

zone. If an external IR receiver is required, purchase a 

5V demodulated IR receiver such as Model 804-052 from 

Audio Authority.

6.3  rs-232 serIal control

Connect a computer or other serial controller to the RS-232 

port on the rear panel using an RS-232 cable. The HMX-

244 serial commands are based on Windows™ OS super 

terminal. Commands include on, off, and source selection 

on any zone output.

Chose the right COM when setting “super terminal” and 

then set the parameters as follows:

 

Baud Rate: 4800 bps 

 

Data bit: 8 Bits 

 

Parity: None

 

Stop Bit: 1 bit

 

Data stream: None

•  Each command should be two or three characters, 

followed by a carriage return. After each command, the 

HMX-244 responds with “successful operation”.

•  The next command must be sent within three seconds or 

the error message: ”Overtime instruction” appears. 

•  If an incorrect command is received, the error: “wrong 

instruction” appears. 

•  If the input or output is not connected or not in powered 

on, “ineffective instruction” appears. 

serIal coMMands

These commands are for the HMX-244 only.  The serial 

port on the Model 1380R receiver is not used.

The character for the zone output (A, B, C, or D) comes 

first, then the number for the source input: 
•  zone 3 to source 2 = C3(carriage return) 
•  zone 1 to source 4 = A4(carriage return), etc.

To turn the HMX-244 on or off enter the following: 
•  ON(carriage return) 
•  OFF(carriage return) 

To query the status of the HMX-244 enter the following:
•  QS(carriage return) 

Important:

 all serial commands must be terminated with a 

carriage return and line feed.

HMX-244

VIDEO MATRIX

1

2

3

4

ZONE 1

OFF

1

2

3

4

ZONE 2

OFF

1

2

3

4

ZONE 3

OFF

1

2

3

4

ZONE 4

OFF

AUTO

POWER

ZONE 

REMOTE CONTROL

HMX-244 VIDEO MATRIX 

1

4

2

3

SELECT 

SOURCE

note:

Use only 5V demodulated IR 

 

receivers such as Model 804-052 

(sold separately)

IR Receiver pinout 

Tip = +5 Volts

Ring = Data

Sleeve = Ground

IR Emitter pinout

Tip = Signal

Sleeve = Ground

Summary of Contents for HMX-244

Page 1: ...NE 1 OUTPUT ZONE 2 OUTPUT ZONE 3 OUTPUT ZONE 4 OUTPUT HDMI SOURCE INPUTS IR SOURCE 4 INPUT SOURCE 3 INPUT SOURCE 2 INPUT SOURCE 1 INPUT IR IR IR IR RS 232 TMDS DDC HDMI A B TMDS DDC HDMI A B TMDS DDC HDMI A B TMDS DDC HDMI A B IR SELECT SOURCE 1 2 3 4 ZONE 4 SELECT SOURCE 1 2 3 4 ZONE 3 SELECT SOURCE 1 2 3 4 ZONE 2 SELECT SOURCE 1 2 3 4 ZONE 1 ...

Page 2: ...ngs To reduce the risk of fire or electric shock do not expose this unit to rain or moisture The exclamation point symbol alerts users to important operating and maintenance instructions in this booklet Read this manual before installing or using this product This product must be installed by qualified personnel Do not open the cover there are no user serviceable parts inside Do not expose this un...

Page 3: ...ance of 130 ft 40m 1380R provides a built in IR receiver that transmits IR commands from the zone to the HMX 244 to switch inputs and to pass IR commands to the sources Input switching can be performed through RS 232 or IR HDMI and HDCP compliant Supports deep color 12 bits per TMDS channel 36 bit sum of all channels Supports 480i p 576i p 720p 1080i p and multiple PC resolutions Supports Dolby Di...

Page 4: ... Panels A Infrared Receiver accepts commands from IR remote controls B Source Selection Button push button cycles through available source inputs C Selected Source Indicator Light indicates the selected source in the specified zone D Power Switch turns matrix off or on E Power Jack connect included 5 5V 4A power supply F HDMI Zone Output connect directly to display and or audio system in nearby zo...

Page 5: ...r Switch turns zone receiver off or on F Power Jack connect included 5V 2A power supply G IR Input Jack connect Model 804 052 IR receiver sold separately to send IR signals over Cat 5 to HMX 244 matrix H HDMI Zone Output connect directly to display or audio system I Cat 5e 6 cables connected to HMX 244 zone output Either TIA EIA 568A or 568B standards may be used provided it is straight through an...

Page 6: ...er HDMI cables perform differently depending on quality of cable and the source equipment used Connect the power adapter to an AC outlet and then to the matrix If you are using the RS 232 control function connect a standard serial cable from the controller to the HMX 244 RS 232 port Turn on the HDMI sources and displays Turn on the matrix and after a pause for HDCP handshaking observe the source s...

Page 7: ...5 RECEIVER CAT 5E 6 CABLES UP TO 130 FT CAT 5E 6 CABLES HDMI CABLE HDMI CABLE ZONE 3 IR RECEIVER SOURCE 1 SOURCE 2 SOURCE 3 SOURCE 4 IR EMITTERS TO SOURCES ZONE 2 1380R CAT 5 RECEIVER CAT 5E 6 CABLES IR SIGNALS IR IR HDMI MATRIX HMX 244 IR Connections VIDEO CONNECTIONS Use only 5V demodulated IR receivers such as Model 804 052 sold separately IR Receiver pinout Tip 5 Volts Ring Data Sleeve Ground ...

Page 8: ...equired purchase a 5V demodulated IR receiver such as Model 804 052 from Audio Authority 6 3 RS 232 serial Control Connect a computer or other serial controller to the RS 232 port on the rear panel using an RS 232 cable The HMX 244 serial commands are based on Windows OS super terminal Commands include on off and source selection on any zone output Chose the right COM when setting super terminal a...

Page 9: ...lity are extremely important in long cable runs where capacitance can severely effect the bandwidth available If a zone is not receiving HDMI signals first make certain that the input cable is as short as possible and none of the output cables are more than 15 meters long Try reducing the resolution color depth and or audio settings Remember that HDMI devices communicate with one another so the so...

Page 10: ...ce Department at 800 322 8346 or 859 233 4599 for assistance in verifying the problem If a defect or potential defect is suspected a replacement unit will be shipped immediately on a defect exchange basis and a Return Authorization Number will be issued for the return of the defective product Replacement units are sent out at the Manufacturer s Suggested Retail Price which is debited to the Custom...

Page 11: ...Audio Authority Model HMX 244 User Manual 11 ...

Page 12: ...E 099 2 11 2048 Mercer Road Lexington Kentucky 40511 1071 Phone 859 233 4599 Fax 859 233 4510 Customer Toll Free USA Canada 800 322 8346 Website http www audioauthority com ...

Reviews: