Installation
Read ‘Safety information’ before installing the fixture.
The fixture is designed for indoor use only and must be used in a dry location with adequate
ventilation. Ensure that none of the fixture’s ventilation slots are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it
where it can be moved or fall over. If you install the fixture in a location where it may cause
injury or damage if it falls, secure it as directed in this user manual using a securely anchored
safety cable that will hold the fixture if the primary fastening method fails.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure
that the surface and all fasteners used can support at least 10 times the weight of all fixtures
and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or
fall over. If you install the fixture in a location where it may cause injury or damage if it falls,
secure it as directed below with a securely anchored safety cable that will hold the fixture if
the primary fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any orientation. When
installing the fixture hanging vertically down, you can use an open-type clamp such as a
G-clamp. When installing in any other orientation, you must use a half-coupler clamp that
completely encircles the truss chord.
To clamp the fixture to a truss:
1. Check that the rigging structure can support at least 10 times the weight of all fixtures and
equipment to be installed on it.
2. Block access under the work area.
3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the
mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through
both mounting bracket legs and be fastened with a self-locking nut.
4. Working from a stable platform, hang the fixture with its clamp on the truss and fasten the
clamp securely.
5. Secure the fixture with a safety cable as directed below.
USER´S
MANUAL
Madison
40FC
7
4
Control Menu Map
MENU
SUB MENU
OPERATION
Addr
d001-d512
RDM/DMX address
CHnL
Stag(11CH)
Channel mode
ArC.1(3CH)
Ar1.d(4CH)
ArC.2(4CH)
Ar2.d(5CH)
Ar2.S(6CH)
HSV(3CH)
SP--
T.(00-99)
Auto program speed increasing
Pr--
Pr01~Pr10
Auto programs
CoLo
C.(01~15)
Color preset
Strb
S.00-s.20
Strobe with spead increasing
rL--
r.(000-255)
Red dimmer
gL--
g.(000-255)
Green dimmer
bL--
b.(000-255)
Blue dimmer
uL--
u.(000-255)
White dimmer
nodE
nod.0
Dimmer speed 0 (no delay)
nod.1
Dimmer speed 1
nod.2
Dimmer speed 2
nod.3
Dimmer speed 3
nod.4
Dimmer speed 4 (slowest speed)
Id
Id.01-Id.66
ID address setting
tEnP
-25~100
Fixture temperature
UErn
Firmware version
rSEt
yes/no
Reset
pnnF
(1.2~24.0)F
PWM refresh rate adjustment(KHz)
DMX Protocol
STAG
11 Channels Mode
Function
Function Control
CH1
Dimmer
000-255: 0-100% dimmer
CH2
Red
000-255: 0-100% Red dimmer
CH3
Green
000-255: 0-100% Green dimmer
CH4
Blue
000-255: 0-100% Blue dimmer
CH5
White
000-255: 0-100% White dimmer