background image

Installation

Read ‘Safety information’ before installing the fixture.

The fixture is designed for indoor use only and must be used in a dry location with adequate 

ventilation. Ensure that none of the fixture’s ventilation slots are blocked.

Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it 

where it can be moved or fall over. If you install the fixture in a location where it may cause 

injury or damage if it falls, secure it as directed in this user manual using a securely anchored 

safety cable that will hold the fixture if the primary fastening method fails.

Fastening the fixture to a flat surface

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure 

that the surface and all fasteners used can support at least 10 times the weight of all fixtures 

and equipment to be installed on it.

Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or 

fall over. If you install the fixture in a location where it may cause injury or damage if it falls, 

secure it as directed below with a securely anchored safety cable that will hold the fixture if 

the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When 

installing the fixture hanging vertically down, you can use an open-type clamp such as a 

G-clamp. When installing in any other orientation, you must use a half-coupler clamp that 

completely encircles the truss chord.

To clamp the fixture to a truss:

1. Check that the rigging structure can support at least 10 times the weight of all fixtures and 

equipment to be installed on it.

2. Block access under the work area.

3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the 

mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through 

both mounting bracket legs and be fastened with a self-locking nut.

4. Working from a stable platform, hang the fixture with its clamp on the truss and fasten the 

clamp securely.

5. Secure the fixture with a safety cable as directed below.

USER´S

MANUAL

Madison 

40FC

7

4

Control Menu Map

MENU

 

SUB MENU

 

OPERATION

 

Addr 

d001-d512 

RDM/DMX address 

 

CHnL 

Stag(11CH) 

 

Channel mode 

ArC.1(3CH) 

Ar1.d(4CH) 

 

ArC.2(4CH) 

 

Ar2.d(5CH) 

Ar2.S(6CH) 

HSV(3CH) 

SP-- 

T.(00-99) 

Auto program speed increasing 

Pr-- 

Pr01~Pr10 

Auto programs 

CoLo 

C.(01~15) 

Color preset 

Strb 

S.00-s.20 

Strobe with spead increasing 

rL-- 

r.(000-255) 

Red dimmer 

gL-- 

g.(000-255) 

Green dimmer 

bL-- 

b.(000-255) 

Blue dimmer 

uL-- 

u.(000-255) 

White dimmer 

 

 

nodE 

nod.0 

Dimmer speed 0 (no delay) 

nod.1 

Dimmer speed 1 

nod.2 

Dimmer speed 2 

nod.3 

Dimmer speed 3 

nod.4 

Dimmer speed 4 (slowest speed) 

Id 

Id.01-Id.66 

ID address setting 

tEnP 

-25~100 

Fixture temperature 

UErn 

 

Firmware version 

rSEt 

yes/no 

Reset 

pnnF 

(1.2~24.0)F 

PWM refresh rate adjustment(KHz) 

DMX Protocol

STAG

11 Channels Mode

 

Function

 

Function Control

 

CH1 

Dimmer 

000-255: 0-100% dimmer 

CH2 

Red 

000-255: 0-100% Red dimmer 

CH3 

Green 

000-255: 0-100% Green dimmer 

CH4 

Blue 

000-255: 0-100% Blue dimmer 

CH5 

White 

000-255: 0-100% White dimmer 

Summary of Contents for 7427244398633

Page 1: ...ss cleaner or distilled water 4 Check that the fixture is dry before reapplying power Fuse Replacement This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel To rep...

Page 2: ...100 dimmer CH2 Red 000 255 0 100 Red dimmer CH3 Green 000 255 0 100 Green dimmer CH4 Blue 000 255 0 100 Blue dimmer CH5 White 000 255 0 100 White dimmer CH6 Strobe 000 255 Strobe with speed increasing...

Page 3: ...oltage in accordance with the specifications in this manual or on the product s specification label Make sure it is grounded when using it Unplug mains lead before opening the housing Make sure that t...

Page 4: ...171 200 Red 100 Green 100 Blue 100 201 220 Colour temperature1 3200K 220 255 Colour temperature2 5600K CH7 Strobe 000 013 Strobe off 014 255 Strobe with speed increasing CH8 Auto program 000 020 no f...

Page 5: ...entation you must use a half coupler clamp that completely encircles the truss chord To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times the weight of all...

Page 6: ...ep 3 Tighten the zoom buttons Securing with a safety cable Secure the fixture with a safety cable or other secondary attachment that is approved for the weight of the fixture so that the safety cable...

Page 7: ...ccesorio est seco antes de volver a aplicar energ a Reemplazo de fusibles Este fusible se encuentra en un portafusible junto a la toma MAINS OUT del panel de conexiones Para reemplazar un fusible 1 De...

Page 8: ...0 199 ID19 231 ID42 254 ID65 200 209 ID20 232 ID43 255 ID66 210 ID21 233 ID44 211 ID22 234 ID45 Tabla de contenido Precauci n 2 Introducci n 2 Instrucciones de seguridad 2 Visi n General 3 Instalaci n...

Page 9: ...oducto Aseg rese de que est conectado a tierra cuando lo use Desconecte el cable de alimentaci n antes de abrir la carcasa Aseg rese de que el cable de alimentaci n nunca est doblado o da ado por bord...

Page 10: ...100 151 170 rojo 100 0 verde 100 0 azul 100 171 200 rojo 100 verde 100 azul 100 201 220 Temperatura de color1 3200K 220 255 Temperatura de color2 5600K CH7 Estrobosc pico 000 013 Luz estrobosc pica a...

Page 11: ...e usar una abrazadera de medio acoplador que rodee completamente el cord n de la armadura Para sujetar la luminaria a un truss 1 Verifique que la estructura de aparejo pueda soportar al menos 10 veces...

Page 12: ...Paso 3 Apriete los botones de zoom Asegurar con un cable de seguridad Asegure la l mpara con un cable de seguridad u otro accesorio secundario que est aprobado para el peso de la l mpara de modo que e...

Reviews: