Triggering and end of a high threshold alarm
‘Intermittent alarm’ type tests detect short but frequent overshoots. A time window and a number of
acceptable overshoots during this time window must be set. For instance, if we do not want more than 5
overshoots within 2 minutes, a counter will start at the 1
st
overshoot. At the 6
th
overshoot within the 2 minute
window, an alarm is sent. The state is reinitialized when the number of overshoots within a 2 minute period is
lesser than or equal to 5.
high threshold
1st overshoot
5th overshoot
time window
time
le
v
e
l
time window
less than 4 overshoots:
no alarm
time window
less than 4 overshoots:
state reinitialization
more than 4 overshoots:
alarm is sent
Intermittent alarms with a maximum of 4 events within the set time window
Notification sequence:
Notifications (or traps) are identified with a unique id number (see trap description, Appendix B). They
include common fields but also specific fields to detail the reason and the context for the notification. The
common fields are:
o
SystemType: GoldenEagleTV