9.2.
AM Analog Scan
Select the ‘AM Scan’ tab or go to the ‘Readings’
’AM Analog Scan’ menu to view the scan and configure
the scan.
Four different scans are displayed in the graphic window
(1)
:
Current scan (in green), most recent scan carried out.
Maximum scan (in red).
Minimum scan (in purple).
Reference scan (in yellow), with which the current scan is compared.
Use the check boxes to display or hide each scan
(2)
.
Five levels of zoom are available. Use
to unzoom
(3)
.
Hover the cursor over the graph to display specific values for all 4 curves.
Before validating the scan alarm function (see section 8.1), a reference scan must be carried out by the unit
(4)
. Click
“New reference scan” to start that scan.
In this section, you may also:
Clear min and max scans.
Run a new current scan.
Set the current scan as reference.
The table gives you the values of the reference scan in text form. This very data can be exported using the
“Export to CSV…” button and viewed in a spreadsheet application such as Microsoft Excel
(5)
.
Monitoring is never interrupted when scanning is in progress.
Scanning is performed in 3 kHz or 5 kHz increments depending on the market the unit was acquired for.