background image

 

GOLDENEAGLE AM 4.0.x user manual 

– 07/2012 

 

 

Page 5 

Head Office 

: Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France) 

Tel +33 (0)5 57 928 928 

– Fax +33 (0)5 57 928 929 –

 

[email protected]

 

– 

www.audemat.com

 

1.2. 

Options 

1.2.1.  Software option 

 

Phone Alerts: 

alarms recorded in the event log and sent by mail or SNMP trap can also be sent 

as phone messages. In addition to the software key, a modem supplied by Audemat is required 
to implement the option. See section 6.2.8.

 

See chapter 12 for software option activation. 

1.2.2.  Hardware options 

Five slots are available in which I/O boards can be installed.

 

 

Digital inputs: 

module with 16 digital inputs on a female SUB-D 25.   

 

Relay outputs: 

module with 8 relay outputs on a male SUB-D 25.

 

 

Analog inputs: 

module with 8 analog inputs on a female SUB-D 25. 

 

 

Interface Type  

Analog 

Digital 

Relay 

Max number of boards 

Number of I/O per board 

16 

Max number of I/O per unit 

80 

40 

 

See chapter 13 for configuration information. 

Summary of Contents for GOLDENEAGLE AM

Page 1: ...audemat WorldCast Systems Group web www audemat com e mail contact audemat com GOLDENEAGLE AM User Manual Software version 4 0 x Date 2012 07 13 Audemat is a registered trademark...

Page 2: ...k configuration using the embedded website 13 3 3 Installing the GOLDENEAGLE AM remote applications 14 4 THE INTERNAL WEBSITE 15 4 1 Product ID 15 4 2 Network 16 4 3 Download 17 5 REMOTE APPLICATION P...

Page 3: ...1 Scan Management 51 8 2 Recording Management 51 9 ACCESSING READINGS 53 9 1 Analog Radio 53 9 2 AM Analog Scan 54 9 3 AM Market Scan 55 10 REALTIME MONITORING 56 10 1 AM Analog Radio 56 10 2 Spectru...

Page 4: ...lity content over IP T1 E1 ISDN Leased Lines Ecreso who design a range of highly efficient transmitters for broadcast transmission technologies such as FM DAB DAB T DMB Both liquid and air cooled opti...

Page 5: ...oftware key a modem supplied by Audemat is required to implement the option See section 6 2 8 See chapter 12 for software option activation 1 2 2 Hardware options Five slots are available in which I O...

Page 6: ...he electrical network is not stable a power conditioner such as a UPS must be used The device must only be used with a plug that incorporates a protective ground contact To avoid any risk of electrocu...

Page 7: ...ent overheating It is strongly recommended that the location is not subject to a high humidity level 70 and to avoid high salinity or chlorinated environments It is strongly recommended that the locat...

Page 8: ...n power supply 100 250 VAC 50 60 Hz Power consumption 60 W 230 VAC Temperature Optimal performance temperatures Guaranteed working temperatures Storage 5 C 45 C 0 C 50 C 20 C 70 C Humidity 10 95 non c...

Page 9: ...ity in the band 0 5 dB Precision 0 5 dB Span 60 kHz FFT calculated with the following parameters Type of FFT Blackman Harris Number of points 2048 Average 5 10 20 50 100 200 2 2 Network configuration...

Page 10: ...com 2 3 List of the included accessories Check that all items are present in the box 1 power supply cable 1 straight Ethernet cable A 1 crossover Ethernet cable B 1 F SMA cable 1 BNC cable C 1 BNC F a...

Page 11: ...the GOLDENEAGLE AM 2 5 Rear Panel Primary interface 192 168 0 100 Secondary interface 172 17 2 172 RJ45 straight Ethernet cable A for the network OR RJ45 crossover Ethernet cable B for a direct connec...

Page 12: ...your PC in the 192 168 xx xx range so it is compatible with the IP address in the GOLDENEAGLE AM 192 168 0 100 The procedure varies depending on your operating system For this if using Windows 2000 or...

Page 13: ...b browser Internet Explorer Mozilla Firefox and enter the unit s IP address login and password Default 192 168 0 100 Admin admin Click on Network in the left menu and update the primary interface IP a...

Page 14: ...sy create scripts to automate and control inputs outputs and to manage alarms MasterView view and control your unit via custom views Do not install ScriptEasy or MasterView if more recent versions are...

Page 15: ...audemat com 4 THE INTERNAL WEBSITE Links on the left side of the page enable easy navigation to the various pages of the site 4 1 Product ID The Product ID page lists the build versions of the various...

Page 16: ...emat com www audemat com 4 2 Network IP configuration definition Current network status current network parameters Ethernet configuration mode The application can be configured for use with a static o...

Page 17: ...omplete configuration of the unit system station and monitoring configuration ScriptEasy automation application for remote control of alarms sent by the GOLDENEAGLE TV management of I Os and creation...

Page 18: ...been detected This method prevents useless alarms from being sent Measured Value Monitoring Parameters Alarms Values Recorded RF Level Nominal level Low threshold 1 Low threshold 2 High threshold hyst...

Page 19: ...hort but frequent overshoots A time window and a number of acceptable overshoots during this time window must be set For instance if we do not want more than 5 overshoots within 2 minutes a counter wi...

Page 20: ...following values channelType 8 AM frequency frequency in kHz x10 530 for 1710 kHz channelId row number of the station in the monitored channel list channelName station name alarmStatus integer indica...

Page 21: ...actual times Channel 2 the error starts second 6 while the channel is monitored and ends second 11 when the channel is no longer monitored An error starts again second 18 and ends second 23 The monit...

Page 22: ...33700 Bordeaux Merignac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com Depending on the version scanning is performed in either 3 kHz increments for the 9 kHz s...

Page 23: ...he Network configuration page see section 7 2 5 The login and password can be modified on the Users configuration page see section 6 2 4 Default values are Admin admin for the administrator and Guest...

Page 24: ...The application may take a few seconds to establish the connection Once connected the software will access data from the unit A simple user will be able to view most system unit and monitoring settin...

Page 25: ...8 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 6 CONFIGURING THE GOLDENEAGLE AM Configuration is reserved for administrators 6 1 Set application preferences Display the options using...

Page 26: ...them but not change anything Click the button Links on the left side of the widow allow the user easy access to the various settings 6 2 1 Product Identifiers The Product ID page lists the build versi...

Page 27: ...month day and time hour minute second Set system time zone The user selects the geographical zone from the list Important to have this set correctly when using an NTP server Network Time Protocol NTP...

Page 28: ...t audemat com www audemat com 6 2 3 Status The Status page gives a summary of the unit s vital parameters temperature available memory CPU load and available disk space This information may be request...

Page 29: ...ftware application Administrator and Guest An Administrator has the rights to change any of the system parameters A Guest will be able to view measurements and alarms but will not be able to change an...

Page 30: ...6 2 5 Network IP Configuration Ethernet configuration mode Both interfaces primary and secondary can be configured with a static or dynamic IP address DHCP Static Ethernet configuration If using a st...

Page 31: ...p This function makes it possible for the unit to switch to the PPP interface to send alarms if the primary Ethernet interface eth0 doesn t function anymore i e if a reference address doesn t answer t...

Page 32: ...s number of calls The user can limit the number of daily outgoing calls He she should put 0 if this limitation is not required The user can limit the number of hourly outgoing calls He she should put...

Page 33: ...ization string is ATQ0V1H0 The Filter Callers function enables incoming calls to be filtered using Caller ID the incoming telephone line must have this service activated Filter Callers To add a new ac...

Page 34: ...gnac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 6 2 8 Phone Alerts option This function activates DTMF phone alerts for ScriptEasy alarms Please refer to ch...

Page 35: ...for example PPP in the case of a modem connection and the new port to use in the duplicate to field Each redirection line can be activated or disabled independently Once the configuration is done lock...

Page 36: ...29 contact audemat com www audemat com The input and output interfaces of the router can be configured by the options Public interface Input and Private Interface output Once the configuration is done...

Page 37: ...red are Webcam enabled activates or deactivates the webcam support Motion sensitivity sensitivity of the movement detection from 1000 to 32000 1000 is the highest sensitivity Mark motion location circ...

Page 38: ...t enables the user to restart the application to reinitialize the parameters Reboot equipment restarts the entire unit Power off equipment enables the unit to be switched off remotely The unit cannot...

Page 39: ...ilable that allow the user to configure the contents of the subject line and the first line of the body of the alarm e mail Any text entered in these windows will be included and there is a list of va...

Page 40: ...sending test sends a Warm start trap to the destination s according to the trap settings 6 2 13 1 Supported SNMP versions The Unit SNMP agent is compatible wiht SNMPv1 and SNMPv2c versions GET and SE...

Page 41: ...trap 6 2 14 Notifications SNMP Actions The user may replay traps that have not been acknowledged yet The user may also delete pending traps that have not been acknowledged yet Configuration depending...

Page 42: ...s soon as the right conditions are met When a new notification appears the frozen notification is reactivated and a cycle of sending attempts begins again The alarm severity level can also be set a sp...

Page 43: ...com 6 2 16 I O Log Set parameters for the I O log that the user can view from the application Status button Event log tab see section 11 2 Settings set recording frequency and length of time event log...

Page 44: ...d activites Kennedy 20 avenue Neil Armstrong F 33700 Bordeaux Merignac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 6 2 18 Receivers On this page view informa...

Page 45: ...mat com www audemat com 7 MONITORING CONFIGURATION Reserved for administrators Click to access the channel configuration pages 7 1 Managing channels 7 1 1 Adding New Channels to the Monitoring List Th...

Page 46: ...erformed click Rescan to initiate a new scan 1 When the scan exists the channel to be added can be selected in the list of detected frequencies 2 The selected program frequency automatically appears y...

Page 47: ...ut alarm will scan the station and keep track of the readings but will not send alerts on out of tolerance conditions Finally if you do not want this particular station to be a part of the regular mon...

Page 48: ...ne represents the readings To change a threshold the hysteresis or the nominal level move the mouse to the end of the corresponding line on the arrow and click and drag The Threshold is the reference...

Page 49: ...lation will only be recorded in the event log The Time out before alarm will configure a delay between an out of tolerance reading and the generation of an alarm which prevents transient and momentary...

Page 50: ...mstrong F 33700 Bordeaux Merignac France Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 8 SCANNING AND RECORDING CONFIGURATION Reserved for administrators Click to acc...

Page 51: ...M band at regular intervals or daily at the same time The triggering mode can be Disabled By interval scanning is launched at regular intervals ranging between 1 min and 24 h By hour scanning is launc...

Page 52: ...tary name An FTP folder is automatically created in the GOLDENEAGLE AM when a recording is made The folder name is the date YYYYMMDD All the recordings made on the same day are saved in this folder Th...

Page 53: ...n menu and select either view the last hour or last day s worth of readings You can also use the calendar to display any days readings over the last 30 days provided the unit was recording readings fo...

Page 54: ...to display or hide each scan 2 Five levels of zoom are available Use to unzoom 3 Hover the cursor over the graph to display specific values for all 4 curves Before validating the scan alarm function s...

Page 55: ...rance Tel 33 0 5 57 928 928 Fax 33 0 5 57 928 929 contact audemat com www audemat com 9 3 AM Market Scan Select the AM Market tab or go to the Readings AM Market menu to view the market scan which giv...

Page 56: ...io menu to instantaneously view levels in graphic form Simply enter the desired frequency it can be any frequency on the AM band even if it has not been previously configured 1 Then click to play and...

Page 57: ...elect the channel from the list or enter directly the frequency and click 1 The Measure button in the Marker box 2 activates the measurement marker feature which allows you to set two markers by click...

Page 58: ...m www audemat com The Display Options box contains 3 o a list control for setting the averaging of the readings o a list control for setting the frequency span of the display o Max Curve and Min Curve...

Page 59: ...emat com www audemat com 10 3 AM Audio Monitoring Select the AM Audio Monitoring tab or go to the Realtime AM Audio Monitoring menu Simply enter the desired frequency After clicking you will get a sho...

Page 60: ...aming menu to instantaneously listen to the audio stream Simply Select the player you wish to use the player embedded with the application or an external player Winamp or any player able to read m3u f...

Page 61: ...com 11 VIEWING THE UNIT STATUS Click to view current alarms and event logs 11 1 Current Alarms Select the Current Alarms tab or go to the Status Current Alarms menu to quickly view current alarms All...

Page 62: ...gs Three logs are available Realtime log list of current events The following information is listed sub system start and end time severity source event type and description The list is refreshed autom...

Page 63: ...number of events to display Warning If the Max line count is 30 only the 30 first events will be listed this number is not a per page number We recommend you use the button It opens a dialog box that...

Page 64: ...e 1 Plug in the modem 2 Insert the CD sent by Audemat upon purchase of the option the following screen will pop up 7 8 8 Close and restart the application 9 Once an option has been activated a new lin...

Page 65: ...de With this mode all common pins are internally linked to the ground When a digital input is connected with the common this input s value switches to 1 otherwise it stays on 0 External power supply m...

Page 66: ...ON 1 Digital input 1 2 Digital input 3 3 Digital input 5 4 Digital input 7 5 Digital input 9 6 Digital input 11 7 Digital input 13 8 Digital input 15 9 Common 10 Common 11 Common 12 Common 13 Not used...

Page 67: ...two outputs NC normally closed and NO normally opened Schematic diagram When the relay is not in use com is linked to the NC output When the relay is activated com is linked to the NO output If your...

Page 68: ...nd of the board Each circuit can support 5 A between 60 V and 60 V A 12 V power supply with a max current of 250 mA is available on pin 13 PIN NUMBER DESCRIPTION 1 COM1 2 NO1 3 NC2 4 COM3 5 NO3 6 NC4...

Page 69: ...used by the unit Voltage V must be applied between one of the analog inputs and the ground Analog input module external connection diagram External connections on SUB D 25pts female connector situate...

Page 70: ...1 5299 15 6 1 11 4 3 1 trapheartBeatOndateTime STRING YYYY MM DD HH MM SS 1 3 6 1 4 1 5299 15 6 1 11 4 3 2 trapsheartBeatOnseverity INTEGER Severity Trap Number 9 Trap Name trapsconfigChanged List of...

Page 71: ...psScriptEasyInfochannel Associated channel 1 3 6 1 4 1 5299 15 6 1 11 4 7 9 trapsScriptEasyInfotransmitter Associated transmitter 1 3 6 1 4 1 5299 15 6 1 11 4 7 10 trapsScriptEasyInfonetwork Associate...

Page 72: ...iptEasyManagerAlarmtransmitterId Associated transmitter Trap Number 41 Trap Name scanning List of variables included in the trap OID Name Type Description 1 3 6 1 4 1 5299 15 6 1 7 0 sysSystemType STR...

Page 73: ...ed in the trap see trap 41 Trap Number 201 Trap Name analogAMRFLow2 List of variables included in the trap see trap 41 Trap Number 202 Trap Name analogAMRFHigh List of variables included in the trap s...

Page 74: ...rting from zero the first channel s ID number is 0 and the 10th channel s ID number is 9 2 Measurements are as follows 0 RF level value in dBuV x10 2 AF level value in dBr x10 For instance to read the...

Page 75: ...ow 3 Possible alarm values are 0 Beginning of error 1 End of error 2 Beginning of alarm 3 Intermittent error alarm 4 End of alarm 5 Alarm closed by hierarchy 6 Alarm reopened by hierarchy 7 Monitoring...

Page 76: ...RE FOR RETRIEVING THE IP ADDRESS If you cannot connect to the embedded web site nor to the remote application use a PC to retrieve and update the GOLDENEAGLE AM s IP address Connect the unit to the po...

Page 77: ...928 Fax 33 0 5 57 928 929 contact audemat com www audemat com Wait for 1 minute for the following screen Enter the password default password is admin and press Enter Select Display current IP configur...

Page 78: ...t audemat com www audemat com APPENDIX D FOR FURTHER INFORMATION Please contact Head office Audemat 20 avenue Neil Armstrong Parc d Activit s J F Kennedy 33700 BORDEAUX MERIGNAC FRANCE Tel 33 5 57 928...

Reviews: