8.1.
Scan Management
Select the ‘Scanning’ tab or go to the ‘Monitoring’
’Scanning’ menu to configure scanning options.
The GOLDENEAGLE AM can automatically scan the AM band at regular intervals or daily at the same time.
The triggering mode can be:
Disabled.
By interval: scanning is launched at regular intervals ranging between 1 min and 24 h.
By hour: scanning is launched daily at a time set by the user.
The unit records the minimum and maximum RF levels of the carriers and triggers an alarm (if validated by
the user) when a RF level change is detected. The minimum RF threshold and the triggering difference are
user-defined.
See section 9.2 to view the scan.