background image

9

Chapter 2

Overview TMP40

The TMP40 is a SourceCon™ compatible module featuring an (internal) board-edge 
connector which carries all signals for getting it connected to any supporting main unit. 

All external in & output connections shall be made using the available connectors on 
the panel.

1) Balanced stereo line output:

The balanced stereo line output is implemented using two 3-pin terminal block 
connectors. The audio output available on this connector allows it to be fed to any 
amplifier or pre-amplifier.

2) F-type antenna connection:

The antenna (input) connection is implemented using an F-type connector whereto the 
supplied FM antenna should get connected. Depending of the installation conditions, 
location and signal strength, it can be recommended / necessary to extend the antenna 
using 75 

Ω

 coaxial cable and connect an external or outdoor antenna.

Summary of Contents for DMP40

Page 1: ...TMP40 User Manual www audac eu ...

Page 2: ...h care and is as complete as could be on the publication date However updates on the specifications functionality or software may have occurred since publication To obtain the latest version of both manual and software please visit the Audac website www audac eu ...

Page 3: ...Waste of Electrical and Electronic Equipment WEEE 7 Chapter 1 Connections and connectors 8 Connection standards 8 Chapter 2 Overview TMP40 9 Chapter 3 Using the TMP40 10 Module screen 10 Settings screen 11 Chapter 4 Installing the TMP40 13 Chapter 5 Additional information 15 Technical specifications 15 Notes 16 ...

Page 4: ...4 ...

Page 5: ...ed channels can be internally stored and recalled Radio station information carried by RDS can be retrieved while other functions such as mono stereo switching FM always guarantee the best possible audio clarity Besides the signal output level which is user configurable the traffic announcement volume can be individually set which guarantees the best intelligibility in specific requiring applicati...

Page 6: ... NOT INSTALL THIS UNIT NEAR ANY HEAT SOURCES SUCH AS RADIATORS OR OTHER APPARATUS THAT PRODUCE HEAT DO NOT PLACE THIS UNIT IN ENVIRONMENTS WITH A HIGH LEVEL OF DUST HEAT MOISTURE OR VIBRATION THIS UNIT IS DEVELOPED FOR INDOOR USE ONLY DO NOT USE IT OUTDOORS ONLY USE ATTACHMENTS ACCESSORIES SPECIFIED BY THE MANUFACTURER UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS O...

Page 7: ...llection point or recycling centre for electrical and electronic waste Do this to make sure that the product is recycled in an environmental friendly way and help to protect the environment in which we all live CAUTION The symbols shown are internationally recognized symbols that warn about potentional hazards of electrical products The lightning flash with arrowpoint in an equilateral triangle me...

Page 8: ... equipment are performed corresponding to international wiring standards for professional audio equipment 3 Pin terminal block For balanced in output connections Left Signal XLR Pin 3 Center Signal XLR Pin 2 Right Ground XLR Pin 1 For balanced line output connections For unbalanced line output connections ...

Page 9: ...anced stereo line output is implemented using two 3 pin terminal block connectors The audio output available on this connector allows it to be fed to any amplifier or pre amplifier 2 F type antenna connection The antenna input connection is implemented using an F type connector whereto the supplied FM antenna should get connected Depending of the installation conditions location and signal strengt...

Page 10: ...tation selection Automatic tuning The currently playing radio station can be selected by pressing the tuning down and tuning up buttons When selected it will automatically start searching for the next station with sufficient signal strength The currently tuned frequency will be indicated at the center of the screen also indicating additional carried RDS information if available such as the current...

Page 11: ...in screen of the device where the TMP40 is installed to Settings screen The settings menu for TMP40 can be loaded by rotating the rotary dial until the settings symbol is highlighted in blue colour When highlighted confirm to proceed to the settings menu by single pressing the rotary dial Gain The gain can be adjusted within a range of 8 dB and 55 dB allowing optimalization of the output level acc...

Page 12: ...wever it will switch automatically to mono mode if the signal reception strength is insufficient This reduces the noise and improves the sound quality when having poor signal reception Manual switching the output to mono mode is possible using this function allowing the output to be fed to mono systems such as 100V public address amplifiers Toggling between mono and stereo mode can be done by sing...

Page 13: ...emoved by releasing the screws on both ends Step 2 Before removing the modules from their protective bag we recommend touching a grounded metal chassis or any other grounded point to prevent electrostatic discharges affecting the sensitive electronic components It is recommended to always hold the module card by the metal connection panel and avoid touching of the components on the circuit board d...

Page 14: ...ectly inserted The module is well inserted when its connection panel touches the metal chassis of the main device where inserted to Step 5 Fasten the module into the slot using the included screws Be aware that damage or malfunctions may occur if the module is not correctly fastened Step 6 Once the module correctly installed the system can be powered on and the module functionality will be automat...

Page 15: ...z Output level 8 dB 55 dB Software configurable Sensitivity 100 dBm Signal noise 42 dB THD N 0 1 Frequency response 30 Hz 15 kHz Crosstalk 42 dB Power consumption 0 5 Watt Dimensions W x H x D 87 x 34 5 x 114 mm Weight 0 071 Kg Packaging Carton box Shipping weight Volume 1 08 Kg 0 028 Cbm Compatible devices XMP44 Modular audio system Optional Accessories ASK10S 4 Way antenna splitter kit RGA10 Omn...