USER MANUAL
8
Modbus TCP Interface (710-14812-00D)
5.
PLC Configuration
The PLC must be configured to map registers within the interface to addresses within
the PLC.
Example mapping of PLC registers to registers within the Modbus TCP Interface
(Target):
The device must be configured directly in the PLC. No additional files are required.
6.
Feedback LEDs
1
2
TX/
R
X 2
TX/
R
X 1
Li
nk
2
Li
nk
1
Err
or
Sta
tu
s
Po
w
er
14702.B
LED
name
LED
Status
Description
Power Off
Device is not powered up.
On
Device is receiving power.
Error
Off
No error.
Flashing System error.
On
Communication error.
Status Off
Not ready.
Slow flash Ready but not configured.
Fast flash Configured and waiting for communication.
On
Communication has been established.
Link x Off
No network connection.
On
Connected to a network.
TX/RX x Flashing Establishing connection.
On
Operating normally.