background image

TH102 TEMPERATURE AND HUMIDITY CONTROLLER 

INSTRUCTION MANUAL  

Version 1.3

AUBER INSTRUMENTS

WWW.AUBERINS.COM

2013.11

P1/3

Instruction Manual

1. Overview

This plug-n-play temperature and humidity controller can be used for 
sausage curing, green house and incubator applications . The 
controller has a two-line LED display, two output sockets, one sensor 
modul e and one input power cord. The top dis pl ay  s hows the 
meas ured temperature val ue and bottom dis play  shows the 
measured humidity value. The left output socket is for heating/cooling 
device. Right output socket is for humidifier/dehumidifier. The sensor 
module contains both temperature and humidity sensor.

* Please  note: Although both temperature and humidity output can 
handle up to 15A, the combined total power of the two channels are 
limited to 1500 Watts due to the limitation of input power cord.

Up Key,Unmute Alarm
Dn Key, Mute Alarm

Set Key

Measured

Humidity

Measured

Temperature

Heating/

Cooling 

Device Socket

Humidifier/
Dehumidifier
Device Socket

Humidifier/
Dehumidifier
On Indicator

Heating/

Cooling Device 

On Indicator

Alarm Indicator, On 
when Alarm Muted

3. Front Panel

2. Specification

 

6

 

8

.

9

 

3

 

6

.

8

5 sec

SET

T

RH

 

tSp

 

5

 

4

.

2

T

RH

 

1

 

5

.

0

 

HSp

RH

T

 

Edt

 

tE

T

RH

 

Edt

 

Hu

T

RH

 

C-F

 

F

T

RH

 

HcM

 

deH

T

RH

Dn
Up

 

tcM

 

CL

T

RH

 

Hdf

 

0

T

RH

 

TdF

 

0

T

RH

 

Hof

 

0

T

RH

 

toF

  

0

T

RH

 

HAh

 

90

.

0

T

RH

 

tAH

32

.

0

T

RH

 

HAL

 

10

.

0

T

RH

 

TAL

 

32

.

0

T

RH

 

HAS

 

0

T

RH

 

tAS

  

0

T

RH

 

HSF

 

off

T

RH

 

tSF

  

oFF

T

RH

 

6

 

8

.

9

 

3

 

6

.

8

T

RH

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

Temperature 
Unit

Temperature 
Control Mode

Temperature 
Differential

Temperature 
Offset

Temperature 
High Limit Alarm

Temperature 
Low Limit Alarm

Anti-short 
Cycle Delay

Temp Sensor 
Failure Operation

Humidity 
Setting

Humidity 
Control Mode

Humidity 
Differential

Humidity 
Offset

Humidity High
Limit Alarm

Anti-short 
Cycle Delay

Humidity Sensor 
Failure Operation

Humidity Low
Limit Alarm

Humidity 

Set Point

Temperature 

Set Point

Temp

Setting

Temperature Control Range -40~80 ° C, -40~176 ° F

Temperature Resolution

0.1 ° C (between -9.9 ~ 80 ° C)
1 ° C (between -40 ~ 10 ° C)
0.1 ° F (between -9.9~99.9 ° F )
1 ° F (between -40 ~ 10 ° F,100 ~176 ° F)

Temperature Accuracy

0.5 ° C

Temperature Control Mode On/Off Control. Heating or Cooling
Temperature Control Output 15A, 120V or 240V AC *
Humidity Control Range

0~99.9% RH

Humidity Resolution

0.1% RH

Humidity Accuracy

3% RH

Humidity Control Mode

On/Off Control. 
Humidifying or Dehumidifying

Humidity Control Output

15A, 120V or 240V AC *

Operating Temperature

0~50 ° C

Dimension

91x140x46mm

Input Power 

85 ~242VAC, 50Hz/60Hz

Sensor Cable Length

6 ft (2m)

Power Cable Length

3 ft (1m)

Figure 1. Front Panel

Figure 2. Flow Chart

4. Setup Flow Chart

When the controller is powered on, it will display the measured 
temperature and humidity. The controller will keep running according 
to  the  saved  setting.  If  the  humidity  or  temperature  sensor  is 
shorted, the controller will display  Err . Please see Figure 2 for the 
flow chart to set the parameters.

Reviews: