TH102 TEMPERATURE AND HUMIDITY CONTROLLER
INSTRUCTION MANUAL
Version 1.3
AUBER INSTRUMENTS
WWW.AUBERINS.COM
2013.11
P1/3
Instruction Manual
1. Overview
This plug-n-play temperature and humidity controller can be used for
sausage curing, green house and incubator applications . The
controller has a two-line LED display, two output sockets, one sensor
modul e and one input power cord. The top dis pl ay s hows the
meas ured temperature val ue and bottom dis play shows the
measured humidity value. The left output socket is for heating/cooling
device. Right output socket is for humidifier/dehumidifier. The sensor
module contains both temperature and humidity sensor.
* Please note: Although both temperature and humidity output can
handle up to 15A, the combined total power of the two channels are
limited to 1500 Watts due to the limitation of input power cord.
Up Key,Unmute Alarm
Dn Key, Mute Alarm
Set Key
Measured
Humidity
Measured
Temperature
Heating/
Cooling
Device Socket
Humidifier/
Dehumidifier
Device Socket
Humidifier/
Dehumidifier
On Indicator
Heating/
Cooling Device
On Indicator
Alarm Indicator, On
when Alarm Muted
3. Front Panel
2. Specification
6
8
.
9
3
6
.
8
5 sec
SET
T
RH
tSp
5
4
.
2
T
RH
1
5
.
0
HSp
RH
T
Edt
tE
T
RH
Edt
Hu
T
RH
C-F
F
T
RH
HcM
deH
T
RH
Dn
Up
tcM
CL
T
RH
Hdf
0
T
RH
TdF
0
T
RH
Hof
0
T
RH
toF
0
T
RH
HAh
90
.
0
T
RH
tAH
32
.
0
T
RH
HAL
10
.
0
T
RH
TAL
32
.
0
T
RH
HAS
0
T
RH
tAS
0
T
RH
HSF
off
T
RH
tSF
oFF
T
RH
6
8
.
9
3
6
.
8
T
RH
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
Temperature
Unit
Temperature
Control Mode
Temperature
Differential
Temperature
Offset
Temperature
High Limit Alarm
Temperature
Low Limit Alarm
Anti-short
Cycle Delay
Temp Sensor
Failure Operation
Humidity
Setting
Humidity
Control Mode
Humidity
Differential
Humidity
Offset
Humidity High
Limit Alarm
Anti-short
Cycle Delay
Humidity Sensor
Failure Operation
Humidity Low
Limit Alarm
Humidity
Set Point
Temperature
Set Point
Temp
Setting
Temperature Control Range -40~80 ° C, -40~176 ° F
Temperature Resolution
0.1 ° C (between -9.9 ~ 80 ° C)
1 ° C (between -40 ~ 10 ° C)
0.1 ° F (between -9.9~99.9 ° F )
1 ° F (between -40 ~ 10 ° F,100 ~176 ° F)
Temperature Accuracy
0.5 ° C
Temperature Control Mode On/Off Control. Heating or Cooling
Temperature Control Output 15A, 120V or 240V AC *
Humidity Control Range
0~99.9% RH
Humidity Resolution
0.1% RH
Humidity Accuracy
3% RH
Humidity Control Mode
On/Off Control.
Humidifying or Dehumidifying
Humidity Control Output
15A, 120V or 240V AC *
Operating Temperature
0~50 ° C
Dimension
91x140x46mm
Input Power
85 ~242VAC, 50Hz/60Hz
Sensor Cable Length
6 ft (2m)
Power Cable Length
3 ft (1m)
Figure 1. Front Panel
Figure 2. Flow Chart
4. Setup Flow Chart
When the controller is powered on, it will display the measured
temperature and humidity. The controller will keep running according
to the saved setting. If the humidity or temperature sensor is
shorted, the controller will display Err . Please see Figure 2 for the
flow chart to set the parameters.