background image

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2017.05                                                                                                                                                                                                          P1/4

 

 

JSL-73B Multi-Event Timer for Beer Brewing 

Version 2.1 (May, 2017) 

 

 

1. 

Overview

 

This timer is designed for home brewing when the brewer needs to follow a 
recipe that calls for ingredients to be added at different time points during the 
wort boiling process. It can help the brewer keep track of time and remind the 
brewer to add ingredients at specific time points. The brewer can simply enter 
the boiling time of each ingredient specified by a beer recipe, the JSL-73B 
timer will automatically convert it to a multi-event timer whose alarm will go off 
at the moment when a new ingredient should be added, as well as when the 
boiling process is supposed to end. The relay output of the timer should be 
connected to an external flashing buzzer which is sold separately. 

 

2. Specifications 

Event timer range: 0 minute to 255 minutes. 
Number of events: 1 to 9. 
Timer accuracy: < 1 s/day. 
Power supply: 90 - 260 V AC or DC. 
Power consumption: < 2 W. 
Relay output: 7 A @ 240 VAC, 10 A @ 120 VAC and 24 VDC (resistive load).  
Average relay life: 100,000 times at rated current. 
Operating temperature: 0 - 60°C. 
Humidity: 0 - 95% RH. 
Panel cutout: 44.5 x 44.5 mm. 
Outer dimension: 48 x 48 x 78 mm. 

 

3.

 

Front

 

Panel

 

 

Figure1. Front panel of JSL-73B timer. 

 

1). Top display window: In normal operation mode, it shows the remaining time 
to the next event. If the remaining time is longer than 99'59”, the display will 
show minutes only. When 

^/MUT

 key is pressed, it will show 

 the number of the upcoming event (e.g., 

t2

t3

...). When an event time is up, it 

will flash the event number (

t2

t3

t4

, and etc.) until the alarm is turned off. In 

programming mode, it shows the name of a parameter. In stopwatch mode (

nE

 

= 1, 

tdIr

 = 

up

), it will display the duration of current event. 

2). Bottom display window:  In normal operation mode, it shows the remaining 
time to the end of all events. If the remaining time is longer than 99’59”, the 
display will show minutes only. In programming mode, it shows the set value of 
the parameter. In stop watch mode, it will display the duration of accumulated 
time that has elapsed. 

3). 

RUN

 indicator: This red indicator should be solid on when the timer is 

running; it flashes when the timer is paused; it should be off when the timer is 
stopped. 

4). 

OUT

 indicator: This green indicator turns on when the relay is on (pull-in); 

turns off when the relay is off (drop-out). This indicator should be synchronized 
with an external flashing buzzer if it was connected to the relay. 

5). 

SET

 key: Press it momentarily to set event timers 

t1

t2

t3

, and so on; 

press and hold it for 1 second to enter the parameter setting mode. In 
parameter setting mode, press it momentarily will go to next parameter setting. 
This key is disabled when timer is running.  

6). 

V/ RST

 key: Reset timer or decrease a parameter value. When the timer is 

running or is showing “END”, press it to stop the timer and reset the timer. In 
the parameter setting mode, press it will decrease the value of a parameter. 
Each time you press and release this key, the value will decrease by one unit. 
When you press and hold it, the value will continuously decrease; as the 
holding time increases, the speed of number decreasing will accelerate. 

7). 

^ / MUT

 key: Mute/cancel the relay, or increase a parameter value.  When 

the timer is running, press this key to allow the coming up event number (

t2

t3

and etc.) to be shown in the top display window. When an event timer is up and 
relay is pulled in, press this key once to release the relay. This key only affects 
the relay. It does not interrupt the running timer. In stopwatch mode, press it to 
restart the count-up timer in the top display window as the second stopwatch. 

In the parameter setting mode, press it to increase the value of a parameter. 
Each time you press and release, the value will increase by one unit. When 
you press and hold it, the value will continuously increase; as the holding time 
increases, the speed of number increasing will accelerate.  

8). 

START

 key: Press it to start the timer. When timer is flashing “END”, press 

it once to stop the flashing, and get the timer ready for the next run. Press the 
START key again will restart the timer. This key is disabled when timer is 
running. In stopwatch mode, press it to start and stop the timer. 

 

 

 

Instruction Manual

 