AUBER INSTRUMENTS
WWW.AUBERINS.COM
2018.08
P2/14
described later, we suggest you connect the hot wire to terminal 10 and neutral
to 9.
3.3 SSR output connection
The SSR control output of the DSPR310D provides a 12 VDC signal that can
control up to 5 SSRs in parallel. Connect terminal 7 to the positive pole of the
SSR (terminal 3 on
Auber’s SSR
s). Connect terminal 6 to the negative pole of
the SSR (terminal 4 on Auber
’s
SSRs). Please make sure the SSR is installed
on the heat sink with proper current rating.
4.
Display Status
Power on
80
100
Display mode 1
rst
n
Display mode 2
Mash
Parameter settings
Display mode 3
Next parameter
goto
Timer reset /
mode selection
Knob
Press
Knob
Knob
Press down and
Hold for 5s
Press
Exit
Exit
Figure 3. Display modes of DSPR310D.
Display mode 1 (Normal operating mode):
1) When MASH indicator is ON
,
the controller is in
step mashing mode
. The top display will show reading
temperature, and it may also flash the remaining time for the current step
alternately (see section 5.2.1). The bottom display will flash set temperature in
this step and current step number (e.g. P-1 for step 1) alternately.
2) When
MASH indicator is OFF
, the controller is in
boiling mode
. The top display will
show reading temperature, and it may also flash the total remaining time of timer
events alternately (see section 5.3.1). The bottom display will flash current output
power percentage (e.g. P50 for 50% power output) and current step number
alternately.
Display mode 2 (Step program reset & Operation mode selection):
This
display mode allows you to reset the timer (mashing and boiling modes), or to
switch between the mashing and boiling operation mode.
A short press of the knob will enter this display mode.
1) The display will show “rSt” on top and “n” at the bott
om. This is the exit menu.
If you enter this mode by accident, you can press the knob again to exit this
display mode without changing anything.
2) Rotate the dial clockwise for one click will change the bottom display to “y”.
This option is to stop the program steps/timer events. Bottom display will flash
“stop”.
It functions the same if you press and hold the Key B for 5 seconds.
3) Rotate the knob with two clicks, the top display will change to “Mode” and
bottom will show “Mash”, which is for step ma
sh mode. Rotate the knob again,
the
bottom display will change to “Boil”, which is for boil mode.
These two menus
are for setting the controller to either step mashing control or boiling control mode.
Press the knob will set the controller to the operation mode displayed. Please
check section 5.1 for details.
Display mode 3 (Parameter settings):
Press down and hold the knob for 5
seconds to enter the display mode 3. Please check section 6 for details.
5.
Operation
5.1 Operation mode selection
This controller offers two operation modes, step mashing and boiling. When the
step mashing mode is selected, the controller functions as a temperature
controller with steps. It automatically adjusts the power output to hold the
temperature at set point in that step. When boiling control mode is selected, the
controller functions as a power regulator. It allows the user to manually adjusting
the power to control the strength of the boil. Figure 4 shows how to select and
switch between these two modes.
rst
n
rst
y
80
100
Knob Press
mode
mash
Rotate
mode
boil
Rotate
Knob
Step Mash
Mode
Boil Mode
Rotate
Knob
Knob
Press
Knob
Press
Knob
Timer Reset
Knob
Press
Exit
Knob
Press
Figure 4. Flow chart for timer reset & operation mode selection.
Press the knob once. The display will show
“
rSt
”
. Rotate the knob with two clicks,
the top d
isplay will change to “Mode” and bottom will show “
Mash*
”.
Press the
knob will set the controller to mashing mode. When mashing mode is selected,
the yellow indicator on the top left corner of the panel will lit. This indicator will
be off if the boiling mode is selected.
Note 1: due to the limitation of 7 segment LED display,
the letter “M”
is displayed as “
m
”.
Note 2: if you mistakenly enter this layer of setting, you need to dial the knob to show:
rst
n
Then press the knob again to exit. Nothing will be changed.
5.2 Step Mashing Operation
5.2.1 Introduction
When first powered up, make sure the controller is in the mashing mode: The
yellow colored mashing mode indicator on the upper left corner should be on,
and the bottom display has no “P” on the left. If not, please change the control
mode to mashing mode as discussed in section 5.1 above. If you were using the
controller in the step mashing mode when powered off last time, the controller
will start in the step mashing mode.
After controller is powered up, the top LED displays the current temperature
reading from the sensor. If temperature sensor is not connected, it will show
“orAL”.
When the step mashing timer is triggered and counting down, the top
display will start to display the current temperature and the remaining time for
the current step alternately. The bottom LED displays your current set
temperature, and it may also flash current step status alternately
, including “run”,
“hold” and “stop”.