Distilling Controller, DSPR400 

Version 1.3 (Sep, 2021) 

 

 

Caution

  

 

This  controller  is  intended  to  control  equipment  under  normal  operating 
conditions.  Failure  or  malfunction  of  the  controller  may  lead  to  abnormal 
operating  conditions,  which  result  in  personal  injury  or  damage  to  the 
equipment  or  other  property.  Devices  (limit  or  safety  controls)  or  systems 
(alarm  or  supervisory)  intended  to  warn  of  or  protect  against  failure  or 
malfunction of the controller must be incorporated into and maintained as part 
of the control system. 

 

Installing the rubber gasket supplied will protect the controller front panel from 
dust and water splash (IP54 rating). Additional protection is needed  for higher 
IP rating. 

 

This  controller  carries  a  90-day  warranty.  This  warranty  is  limited  to  the 
controller only. 

 

1.

 

Specifications 

Input type 

RTD (Resistance Temperature Detector): Pt100 

Accuracy 

±  0.2% full scale 

Temperature 
range 

-328° F ~ +932° F, -200° C ~ +500° C 

Response time 

 0.5s (when FILt =1)  

Display 
resolution 

1° C or ° F for Mashing Mode.  0.1° C or ° F for distilling 
Mode. 

Control mode 

Mashing, Distilling 

Alarm function 

Process/derivation high/low alarm, Acceleration and 
timer alarm, Latching/pulse action,  

Alarm output 

Relay contact: 3A for resistive load. 1A for inductive 
load 

Power supply 

85~260VAC/50~60Hz 

Power 
consumption 

 5 Watt 

Working Ambient 
temperature 

0~50ºC, 32~122ºF 

Dimension 

48 x 48 x 100 mm (W x H x D, from the front panel to 
the back) 

Mounting cutout 

45 x 45 mm 

 

2.

 

Front Panel 

8

5

4

1

2

3

7

6

9

 

 

Figure 1. The front panel of DSPR400 

1). Top display.

 This display indicates the temperature sensor read out value. 

When timer is activated, it will show time and temperature alternately. 

2). Bottom display.

 In distilling mode, this display will show the percentage of 

power being sent to the external SSR after the initial heat up phase. In mashing 
control mode, this display will show the set temperature. 

3). Temperature setting adjusting indicator.

 This is the small dot at the lower 

right corner. In mashing mode, when temperature set point is adjusted, it will 
start  to  flash.  It  reminds  you  that  you  need  to  press  the  knob  to  confirm  the 
change. Otherwise, the temperature setting will return back in 2 seconds after 
you stop the adjustment.  

4). AL1 indicator

. This red LED indicates the status of Relay 1 (AL1). When it 

is on, the relay is closed; when it is off, the relay is open. 

5). AL2 indicator

. This red LED indicates the status of Relay 2 (AL2). When it 

is on, the relay is closed; when it is off, the relay is open. 

6).  Mashing  mode  indicator  (MASH). 

This  yellow  LED  light  indicates  the 

operation mode of the controller. When it is on, controller is in mashing mode; 
when it is off, controller is in distilling mode.  

7). Output indicator (OUT).

 This green LED light is synchronized with output. It 

shows how much power the regulator is sending out (as a 12VDC control signal 
pulse through terminal 6 and 7). When it is on solid, the output is 100% on. When 
it  is  off,  there  should  be  no  output.  When  it  is  flashing,  the  frequency  of  the 
flashing is an indication of high or low power output. Higher frequency means 
higher power output.  

8). Rotary switch (knob).

 Turn it clockwise to increase the output power (or 

selected parameter value); turn it counter-clockwise to reduce the output power 
(or selected parameter value). Press it briefly to reset the timer (if enabled) and 
to switch between mashing and distilling mode. Press and hold it for 5 seconds 
to enter parameter settings menu. Please see section 6 for details. 

9). Function key A & B.

 

There are two Function Keys named “A” and “B” can 

be used to reset/cancel relays. “A” is for Relay 1, Key “B” is for Relay 2

. Please 

check note 20. 
 

3.

 

Wiring Terminals 

The pin assignment of the back terminals of DSPR400 is shown in Figure 2.  

1
2
3

13 14 6

7
8
9

10

4
5

AL1

AL2

AC

85~260V

SSR

+

-

RTD

R

R

W

 

Figure 2. Terminal assignments of DSPR400.  

 

3.1 Sensor connection 

DSPR400 only accepts Pt100 RTD temperature sensor. For a three-wire RTD 
with  standard  DIN  color  code,  the  two  red  wires  should  be  connected  to  the 
terminals 3 and 4. The white wire should be connected to terminal 5. For a two-
wire RTD, the wires should be connected to terminals 4 and 5. Jump  a wire 
between terminals 3 and 4.  
 

3.2 Power to the controller 

The power cables should be connected to terminals 9 and 10. Polarity does not 
matter. It can be powered by 85-260V AC power source. Neither a transformer 
nor jumper is needed to wire it up. For the consistent with the wiring example 
described later, we suggest you connect the hot wire to terminal 10 and neutral 
to 9. 
 

Instruction Manual

 

 

Summary of Contents for DSPR400

Page 1: ...ature setting will return back in 2 seconds after you stop the adjustment 4 AL1 indicator This red LED indicates the status of Relay 1 AL1 When it is on the relay is closed when it is off the relay is...

Page 2: ...n mode selection This controller offers two operation modes mashing and distilling When the mashing mode is selected the controller functions as a temperature controller It automatically adjusts the p...

Page 3: ...system configuration The same type of parameter may have slightly different names when used in different mode For example the timer setting in mashing mode is called t while this parameter is called d...

Page 4: ...ed counting it will continue even if the temperature drops below this start temperature The timer can be reset to start from beginning again To reset the timer press the knob momentarily the display w...

Page 5: ...se this feature set dAST to 0 so this controller will work as a manual mode controller over the entire temperature range Note 11 Timer Function dt dtSP This timer function allows the controller to sho...

Page 6: ...the user to control external contactors and so to employ extra heating elements during acceleration phase The Relay 2 AL2 can be set to act in synchronization with the timer for mashing or boiling dis...

Page 7: ...Suppression determines whether a relay action should be suppressed when controller is just powered up When SiL is set to Y Relay Silence is enabled when SiL is set to N Relay Silence is disabled Rela...

Page 8: ...s temperature is less than 197 F relay will drop off For the low limit alarm relay will pull in when process temperature is less than 100 F and the relay will drop off when process temperature is grea...

Page 9: ...tor 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W 3 4 120V AC L N Heater SSR 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W Heater 240V AC L1 L2 3 4 SSR Figure 11 Wiring examples of controlling a heater with SSR and DSP...