Auber Instruments DSPR400 Instruction Manual Download Page 2

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2021.09                                                                    

   

                                                              P2/9 

 

3.3 SSR output connection 

The  SSR  control  output  of  the  DSPR400  provides  a  12V  DC  signal  that  can 
control up to 5 SSRs in parallel. Connect terminal 7 to the positive pole of the 
SSR (terminal 3 on 

Auber’s SSR

s). Connect terminal 6 to the negative pole of 

the SSR (terminal 4 on the Auber SSRs). Please make sure the SSR is installed 
on the heat sink with proper current rating. 
 

4.

 

Display Status 

  

Power on

80

.

0

 100

Display mode 1

rst

n

Display mode 2

Mash

Parameter settings

Display mode 3

Next parameter

Goto

Timer reset / 

mode selection

Knob

Press

Knob

Knob

Press down and 

Hold for 5s

Press

Exit

Exit

 

Figure 3. Display modes of DSPR400 

 

Display mode 1 (Normal operating mode):

 When power is turned on, the top 

display window shows the current sensor temperature reading. When timer is 
activated, the top display will be switched between the current temperature and 
current time alternately. In mashing mode, the bottom display will show your set 
temperature. In distilling mode, the bottom display will show the current power 
output in percentage (e.g. 50 for 50% power output). Please check section 5 for 
how to adjust set temperature/power. 
 

Display mode 2 (Time reset & Operation mode selection):

 This display mode 

allows you to reset the timer, or to switch between the mashing and  distilling 
operation mode.  
 
A short press of the knob will enter this display mode.  
 

1) The display will show “rSt” on top and “n” at the bottom. This is 

the exit menu.  

If you enter this mode by accident, you can press the knob again to exit this 
display mode without changing anything. 
 

2) Rotate the dial clockwise for one click will change the bottom display to “y”. 

This menu is to reset the timer.  Press the knob will reset the timer. It has two 
purposes. A) If you want to use the timer as regular timer without correlation to 
the temperature, you can start the timer at any time by the reset button. B) After 
timer is timed up and process ended, you can restart the process again by the 
reset button instead of power off the system and power it on again.  
 

3) Rotate the knob with two clicks, the top display will change to “Mode” and 
bottom will show “Mash*”.  Rotate the knob again, the bot

tom display will change 

to “

dStL

”.

 These two menus are for setting the controller to either mashing control 

or distilling control mode. Press the knob will set the controller to the operation 
mode displayed. Please check section 5.1 for details. 
 

Display mode 3 (Parameter settings):

 Press down and hold the knob for 5 

seconds to enter the display mode 3. Please check section 6 for details. 
 

5.

 

Operation 

5.1 Operation mode selection

 

This  controller  offers  two  operation  modes,  mashing  and  distilling.  When  the 
mashing mode is selected, the controller functions as a temperature controller.  
It automatically adjusts the power output to hold the temperature at set point.  
When  distilling  control  mode  is  selected,  the  controller  functions  as  a  power 
regulator.    It  allows  the  user  to  manually  adjusting  the  power  to  control  the 
strength of the boil. The temperature resolution for mashing mode is 1 degree; 
for  distilling  mode  is  0.1  degree.  Figure  4  shows  how  to  select  and  switch 
between these two modes. 

 

rst

n

rst

y

80

100

Knob Press

mode

mash

Rotate

mode

DSTL

Rotate

Knob

Mash Mode

Distill Mode

Available if timer 

is enabled 

(

TF

 =

on

)

Available if timer 

is enabled 

(

TF

 =

on

)

Rotate

Knob

Knob

Press

Knob

Press

Knob

Timer Reset

Knob

Press

 

 

Figure 4. Flow chart for time reset & operation mode selection 

 

Press the knob once. The display will show 

rSt

. Rotate the knob with two clicks, 

the top d

isplay will change to “Mode” and bottom will show “

Mash*

”.  

Press the 

knob will set the controller to mashing mode. When mashing mode is selected, 
the yellow indicator on the top left corner of the panel will lit.  This indicator will 
be off if the distilling mode is selected. 
 

Note*: due to the limitation of 7 segment LED display, 

the letter “M”

 

is displayed as “

m

”.

 

 

5.2 Mashing Operation 

When first powered up, make sure the controller is in the mashing mode: The 
yellow colored mashing mode indicator on the upper left corner should be on, 

and the bottom display has no “P” on the left. If 

not, please change the control 

mode to mashing mode as discussed in section 5.1 above. If you were using the 
controller in the mashing mode when powered off last time, the controller will 
start in mashing mode.   
 
After  controller  is  powered  up,  the  top  LED  displays  the  current  temperature 
reading from the sensor. If temperature sensor is not connected, it will  show 

“orAL”

. The bottom LED displays your set temperature. To adjust its value, just 

rotate the knob. Once the value of the setting is changed, a small dot on the right 
bottom corner will be flashing. It tells you that the setting has been changed but 
not confirmed. After you adjust the temperature to the desired number, 

push the 

knob to confirm the change

. After confirmation, the new setting will remain on 

the display and the dot will be turned off. If you forgot to push the dial, the display 
will return to original set temperature after 2 seconds. The set point will remain 
unchanged. This mechanism is for preventing temperature set point change by 
accident. 
 
The Output indicator will stay on solid right after powered up. This mean the 
controller is heating up the kettle at maximum speed. Once the temperature is 
getting close to the set point, the output indicator will start to flash at slower rate 

Summary of Contents for DSPR400

Page 1: ...ature setting will return back in 2 seconds after you stop the adjustment 4 AL1 indicator This red LED indicates the status of Relay 1 AL1 When it is on the relay is closed when it is off the relay is...

Page 2: ...n mode selection This controller offers two operation modes mashing and distilling When the mashing mode is selected the controller functions as a temperature controller It automatically adjusts the p...

Page 3: ...system configuration The same type of parameter may have slightly different names when used in different mode For example the timer setting in mashing mode is called t while this parameter is called d...

Page 4: ...ed counting it will continue even if the temperature drops below this start temperature The timer can be reset to start from beginning again To reset the timer press the knob momentarily the display w...

Page 5: ...se this feature set dAST to 0 so this controller will work as a manual mode controller over the entire temperature range Note 11 Timer Function dt dtSP This timer function allows the controller to sho...

Page 6: ...the user to control external contactors and so to employ extra heating elements during acceleration phase The Relay 2 AL2 can be set to act in synchronization with the timer for mashing or boiling dis...

Page 7: ...Suppression determines whether a relay action should be suppressed when controller is just powered up When SiL is set to Y Relay Silence is enabled when SiL is set to N Relay Silence is disabled Rela...

Page 8: ...s temperature is less than 197 F relay will drop off For the low limit alarm relay will pull in when process temperature is less than 100 F and the relay will drop off when process temperature is grea...

Page 9: ...tor 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W 3 4 120V AC L N Heater SSR 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W Heater 240V AC L1 L2 3 4 SSR Figure 11 Wiring examples of controlling a heater with SSR and DSP...

Reviews: