background image

8

Configuration: NDMP

Summary of Contents for FastStream NDMP 4600

Page 1: ...ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manual may be reproduced in any form or by any means without the express w...

Page 2: ......

Page 3: ......

Page 4: ...iscover the IP address Begin initial configuration 2 1 Setting up NDMP 7 Automatic NDMP setup Customized NDMP setup 2 2 Remote system monitoring 9 E mail notification Simple Network Management Protoco...

Page 5: ...summary 23 5 1 2 General use commands 27 Help Password ReadOnlyPassword ReadOnlyUsername RestoreConfiguration SaveConfiguration Username VerboseMode 5 1 3 Diagnostic commands 29 BridgeModel BridgeName...

Page 6: ...ntenance commands 33 Date FirmwareRestart MaxOpTemp MinOpTemp OpTempWarn Password Reserve RestoreConfiguration SCSIPortReset SNTP SNTPServer Time TimeZone Username 5 1 5 Serial port configuration comm...

Page 7: ...DMPAuthType NDMPMaxVersion NDMPPortNumber NDMPStatus 5 1 10 Mapping commands 42 AutoMap AutoMapOnBoot DeleteAllMaps Route RouteDisplay Appendix A Cabling i SCSI cabling Cable types Examples Connecting...

Page 8: ...gement Application DMA The DMA controls the NDMP session There is a master slave relationship between the DMA and the data tape servers The FastStream NDMP 4600 implements the Tape Service along with...

Page 9: ...ctor Dual independent Ultra320 LVD SE SCSI busses with VHDCI connectors Backwards compatible with all low voltage differential and single ended SCSI devices Supports NDMP V4 0 IP v 4 compliant with IE...

Page 10: ...supports all SCSI devices including hard disk drives tape drives RAID controllers and DVD MO and CD libraries Ethernet interface The four independent 100 1000 Ethernet RJ45 data ports are labeled Ethe...

Page 11: ...solid on represents a link is present blinking indicates activity and off shows no link is present SCSI activity is indicated for each port on indicates activity off shows no activity Exhibit 1 1 1 L...

Page 12: ...plus the power draw of the other equipment in the rack must not overload the supply circuit and or wiring of the rack 5 Turn on the power switch on the FastStream NDMP 4600 6 Wait up to two minutes fo...

Page 13: ...6 Installation Exhibit 2 0 1 Install the FastStream NDMP 4600 into a rack using the brackets provided supplied by ATTO supplied by ATTO FastStream front...

Page 14: ...ers for each data port you wish to use and the NDMP authorization type for all ports The default NDMP port number is 10000 Automatic NDMP setup 1 If you are not already in the ExpressNAV GUI type the...

Page 15: ...8 Configuration NDMP...

Page 16: ...an event occurs that warrants E mail notification the FastStream NDMP 4600 scans each of its ports until the E mail is sent successfully Each attempt takes one minute The E mail function only sends me...

Page 17: ...Refer to Diagnostic commands on page 29 for detailed information on the commands which regulate SNMP on the FastStream NDMP 4600 Contact your network administrator for the MIB software and appropriate...

Page 18: ...d to a user name and password significant to you 1 If you are not already in the ExpressNAV GUI type the IP address of your FastStream NDMP 4600 as found in Discover the IP address on page 5 in a stan...

Page 19: ...ere all on different physical LANs This creates a network that is independent of physical location allows grouping of users into logical workgroups increases efficient use of resources and adds securi...

Page 20: ...host or the FastStream NDMP 4600 until the display returns the Ready prompt Interrupting the flash process will make your FastStream NDMP 4600 inoperable and you will have to return it to ATTO Technol...

Page 21: ...14 Firmware update...

Page 22: ...aleon and KHTML including Konqueror and Safari The minimum requirements are Internet Explorer 5 5 and Netscape 6 2 for the Windows operating system and Safari 1 2 or Internet Explorer 5 2 for Mac OS X...

Page 23: ...ernet port icon Ethernet ports icon Serial port icon Product faceplate graphic provides links to specified ports Submit button same as typing all CLI commands and saveconfigruation norestart Parameter...

Page 24: ...port independently for the following parameters Enable disable DHCP IP address gateway subnet mask and Ethernet speed MTU Add a VLAN ID and name or delete a VLAN configuration Refer to Discover the IP...

Page 25: ...the FastStream NDMP 4600 and makes permanent any changes you have made since the last firmware restart 1 Click the Restart button A box tells you to wait until the counter gets to 0 and then the brows...

Page 26: ...e only displayed at start up The last line in the start up message sequence is Ready See the example in Exhibit 5 on page 20 Note In serial port sessions there is no prompt on the line below the word...

Page 27: ...release date Mar 9 2006 17 54 13 Build 001C Base version 9 00 255 Megabytes of RAM Installed 4 GbE Data Port s 2 Ultra320 SCSI Interface Port s World Wide Name 20 00 00 10 86 30 01 78 Serial Number I...

Page 28: ...s to get commands are specified in the Results field for each command followed by Ready The set form is an action that changes the value of a parameter or configuration setting It may require a SaveCo...

Page 29: ...mand Type Help for command list ERROR Wrong Missing Parameters Usage usage string ERROR Command Not Processed Exhibit 5 1 2 If you enter a parameter for a CLI command incorrectly the CLI help file dis...

Page 30: ...ll all set displayeventlogfilter gen info 29 DisplayTraceLog displaytracelog 29 DisplayTraceLogFilter all all all set displaytracelogfilter all all chkcond 29 DPMTU 1514 set dpmtu all 9014 37 DumpConf...

Page 31: ...user set readonlyusername 37 Reserve reserve 33 RestoreConfiguration restoreconfiguration default 27 33 RMON get rmon 3 1 31 Route route NDMP default 2 SCSI 1 3 42 RouteDisplay routedisplay NDMP 42 S...

Page 32: ...SNTP enabled get sntp 34 SNTPServer 192 43 244 18 set sntpserver 129 6 15 28 34 TailEventLog taileventlog 34 31 Temperature get temperature 31 Time set time 03 32 30 34 TimeZone EST set timezone pst 3...

Page 33: ...26 Interfaces CLI...

Page 34: ...sions User name is case insensitive 1 32 characters with no spaces Default user set ReadOnlyUsername username Requires a SaveConfiguration command get ReadOnlyUsername RestoreConfiguration Restores co...

Page 35: ...ommand line interface Disabling this option removes parameter names from action commands and removes descriptions from information commands Choices are enabled or disabled Default enabled returns have...

Page 36: ...cape to disable the command begin new log entries and return to CLI DisplayEventLog DisplayEventLogFilter Filters the display of data using the DumpEventLog command for specific FastStream NDMP 4600 s...

Page 37: ...NotifyAddress index all EmailPassword Configures the password used to authenticate the login to the SMTP E mail server The password must not be more than 64 characters A password is not required if th...

Page 38: ...rval 1 3600 Default Refer to Exhibit 5 1 7 on page 38 set RMON idx bucketsRequest interval valid invalid Usage for entire table get RMON ethernetStat historyControl idx Usage for single index entry ge...

Page 39: ...ed Ifdisabled issetforaport no trace log entries for the port are captured set TraceLogFilter SCSI all sb all disabled chkcond all get TraceLogFilter SCSI all sb all Voltage Displays the current level...

Page 40: ...Requires a SaveConfiguration command get MinOpTemp OpTempWarn Controls the number of degrees in Celsius before a thermal control event handling occurs Warnings are made via system log entries Valid e...

Page 41: ...er physical real time clock or manual initialization synchronization Alternative auxiliary time servers 129 6 15 28 www time a nist gov 132 163 4 101 www time a timefreq bidrdoc gov Default 192 43 244...

Page 42: ...he number of data bits per character is fixed at 8 with no parity Choices are 9600 19200 38400 57600 and 115200 Default 115200 set SerialPortBaudRate 9600 19200 38400 57600 115200 Requires a SaveConfi...

Page 43: ...36 Interfaces CLI...

Page 44: ...ess DPn mp1 all IPDHCP Selecting DHCP allows the FastStream NDMP 4600 to request an IP address from the network DHCP server The network must have at least one DHCP server Default enabled set IPDHCP DP...

Page 45: ...for historyControl interval 1 3600 Default historyControl table buckets and interval in hexadecimal Default Refer to Exhibit 5 1 7 set RMON idx bucketsRequest interval valid invalid Usage for entire t...

Page 46: ...ble SCSI ports and their current status Valid status values are O K and Failed SCSIPortList SCSIPortReset Resets the specified SCSI bus SCSIPortReset sb SCSIPortResetOnStartup Specifies whether the SC...

Page 47: ...und or to online if a device is found at the respective SCSI address SCSITargets sb VirtualDriveResponse Allows the FastStream NDMP 4600 to provide proxy responses to SCSI INQUIRY and TEST UNIT READY...

Page 48: ...which the FastStream NDMP 4600 negotiates for each Ethernet data port Default 4 set NDMPMaxVersion DPn all 3 4 Requires a SaveConfiguration command get NDMPMaxVersion NDMPPortNumber Controls the NDMP...

Page 49: ...maps each device to its own auto named target AutoMap default Target Name AutoMapOnBoot Controls automatic device detection and mapping automap at FastStream NDMP 4600 startup Default enabled set Auto...

Page 50: ...drives the distance from the tower to the host must be 5 meters Note UltraSCSI is very sensitive to SCSI bus noise cable distances and the number of devices connected on the SCSI bus Carefully connec...

Page 51: ...astStream NDMP 4600 is terminated internally Ethernet connections Use at least Cat 5e cable to connect the Ethernet ports to your network Note For best performance all cabling network interface cards...

Page 52: ...ion of the Internet Initiator Device A component which originates a command NDMP Internet SCSI Small Computer System Interface a protocol to link data storage facilities over the Internet or an intran...

Page 53: ...ports 4 4 3 1 1 Number of SCSI ports NA 2 2 1 1 SCSI interface NA LVD SE LVD SE LVD LVD Number of FC ports 2 NA NA NA NA FC interface SFP NA NA NA NA Data transfers 4 Gigabit NA NA NA NA Ethernet inte...

Page 54: ...PCI board rackmount desktop Full duplex data transfers Yes Yes Yes Yes Yes Supports Class 2 transfers Class 3 transfers intermix transfers direct fabric connect error recovery Yes Yes Yes Yes Yes Yes...

Page 55: ...product s will be the customer s responsibility This warranty is made in lieu of any other warranty express or implied Manufacturer disclaims any implied warranties of merchantability or fitness for a...

Page 56: ...which are designed to provide a reasonable protection against such interference when operating in a commercial environment Operation of this equipment in a residential area is likely to cause interfe...

Page 57: ...tion of Council Directive 89 336 EEC Standard s to which conformity is declared EN55022 EN5024 CE60950 This Declaration will only be valid when this product is used in conjunction with other CE approv...

Page 58: ...ix ATTO Technology Inc FastStream Installation and Operation Manual...

Reviews: