background image

 

35 | 

P a g e

 

 

IPGateway 

IPGateway controls the current default gateways used by any 
Ethernet port(s). If IPDHCP is enabled, the 'get' command reports 
the current IP gateway assigned by the network DHCP server.  

Default: 0.0.0.0 

set IPGateway [mp[n]] [xxx.xxx.xxx.xxx] 

Requires a SaveConfiguration Restart command 

get IPGateway [mp[n] |all] 

IPSubnetMask 

IPSubnetMask controls the current subnet masks used by any 
Ethernet port(s). If IPDHCP is enabled, the 'get' command reports 
the current IP subnet mask assigned by the network DHCP server.  

Default: 255.255.0.0 

set IPSubnetMask [mp[n]] [xxx.xxx.xxx.xxx] 

Requires a SaveConfiguration Restart command 

get IPSubnetMask [mp[n] |all] 

IsReserved 

IsReserved displays the reservation status of the current services 
session/interface.  

IsReserved 

MaxOpTemp 

Regulates/displays the maximum enclosure temperature alarm 
of the XstreamCORE in degrees Celsius. If the temperature of the 
XstreamCORE rises above the maximum MaxOpTemp, thermal 
control event handling occurs. Valid entries are between 75 
degrees and 90 degrees. 

Default: 90 

set MaxOpTemp [75-90] 

Requires a SaveConfiguration Restart command 

get MaxOpTemp 

MinOpTemp 

Regulates/displays the minimum enclosure temperature alarm of 
the XstreamCORE in degrees Celsius.Valid entries are between 0 
degrees and 15 degrees. 

Default: 0 

set MinOpTemp [0-15] 

Requires a SaveConfiguration Restart command 

get MinOpTemp 

OEMConfigFile 

Returns the “name” (the contents of the first record) of the OEM 
configuration file stored in persistent memory. 

get oemconfigfile 

OpTempWarn 

Regulates/displays the number of degrees in Celsius before a 
warning is sent to the user. Valid entries are between 0 degrees 
and 15 degrees. 

Default: 10 

set OpTempWarn [0-15] 

Requires a SaveConfiguration Restart command 

get OpTempWarn 

Password 

Specifies password for all non-serial sessions: Telnet, FTP and 
XstreamVIEW™ interface. You are prompted for the current 
password, to enter the new password, and to confirm the new 
password. If local Echo is enabled, password echoes all * 
characters. If VerboseMode has been enabled, CLI requests that 
you re-enter the password. When the password is all 0s, Telnet 
and FTP do not validate the password and MD5 authentication is 
disabled.Configure an empty password by pressing the Enter key 
when prompted for the new password and the new password 
confirmation.Passwords are case sensitive and can be 1-32 
characters long with  
no spaces. 

Default: Password 

set Password  

Requires a SaveConfiguration command 

Performance 

Returns system performance data. Data consists of the average 
rate (MB/s) and number of I/Os (IO/s) measured over the 
previous sampling period (approximately one second). Successful 
SCSI Read (28h, 88h, A8h) and Write (2Ah, 8Ah, AAh) commands 
are considered I/Os. Factors that may affect reported 
performance include port availability and saturation, transfer 
size, target device speeds, and overall system utilization. 

get Performance 

Ping 

Sends an ICMP echo request to the specified host. 

Ping [mp[n] [IP Address] <count <size>> 

 

 

Summary of Contents for ATTO XstreamCORE FC 7500

Page 1: ... to 12 Gigabit SAS Storage Controller ATTO XstreamCORE FC 7600 32 Gigabit Dual Fibre Channel to 12 Gigabit SAS Storage Controller 2018 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology Inc 10 2018 PRMA 0464 000MD ...

Page 2: ... ports 8 Management ports 8 LED indicators 8 ATTO XstreamCORE FC 7550 10 Dimensions 10 Cooling and airflow 10 Power 10 Fibre Channel ports 10 SAS SATA ports 10 Management ports 10 LED indicators 10 ATTO XstreamCORE FC 7600 12 Dimensions 12 Cooling and airflow 12 Power 12 Fibre Channel ports 12 SAS SATA ports 12 Management ports 12 LED indicators 12 Install the XstreamCORE 14 Unpack the packing box...

Page 3: ...rovide error notification 22 Update Firmware 23 Using XstreamVIEW 23 Using FTP 23 Interface Options 24 Using XstreamVIEW System Manager 24 Opening an XstreamVIEW session 24 Optimizing XstreamVIEW in Internet Explorer 24 Using the serial port 25 Using Telnet 25 Appendix A Cabling 26 SAS SATA connections 26 Fibre Channel connections 26 Serial port connections 26 Ethernet connections 26 Appendix B CL...

Page 4: ...ompliance with ICES 003 39 Compliance with EN Regulations 39 Appendix D Standards and Compliances 7600 40 Regulatory Notices 40 FCC Notices US only 40 Compliance with ICES 003 40 Compliance with EN Regulations 40 ...

Page 5: ... XstreamCORE FC 7500 is a 16 Gigabit Fibre Channel to 12 Gigabit SAS storage controller configured with two independent 16Gb Fibre Channel ports and four 12Gb x4 SAS connectors Designed to integrate industry leading performance and SAN capabilities into the future generation of storage solutions the XstreamCORE FC 7500 uses a high performance architecture suited for OEMs looking to incorporate SAS...

Page 6: ...nel ports which auto negotiate to 4Gb 8Gb or 16Gb Fibre Channel Ability to aggregate up to 4 hosts without an external switch SFP Fibre Channel modules included Dual Power Supply Full support for FC Fs FCP 3 Support for direct connect to F port switches Four independent 12Gb SAS SATA x4 mini SAS HD connectors which auto negotiate to 3Gb 6Gb or 12Gb Automatic LUN Mapping Patented Drive Map Director...

Page 7: ...el ports which auto negotiate to 8Gb 16Gb or 32Gb Fibre Channel Ability to aggregate up to 2 hosts without an external switch SFP Fibre Channel modules included Dual Power Supply Full support for FC Fs FCP 3 Support for direct connect to F port switches Four independent 12Gb SAS SATA x4 mini SAS HD connectors which auto negotiate to 3Gb 6Gb or 12Gb Automatic LUN Mapping Patented Drive Map Director...

Page 8: ...P connectors and multimode fiber optic cable Make sure all cables are anchored securely at both ends with the proper connectors SAS SATA ports The four x4 12Gb s SAS SATA connectors connect storage devices into the Storage Area Network SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ ...

Page 9: ...s ready and OFF to show not ready Alert A lit yellow LED indicates an alert condition Fibre Channel Port Activity A lit green FC port activity LED indicates FC traffic on the port and OFF indicates no port activity Fibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 16Gb s Green 8Gb s and OFF 4Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates...

Page 10: ...torage devices into the Storage Area Network SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ 45 connectors or the RS 232 serial header console port accessible from the serial RJ 45 connector LED indicators LED indicators can be viewed from the connector side and the front side of the...

Page 11: ...icates FC traffic on the port and OFF indicates no port activity Fibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 16Gb s Green 8Gb s and OFF 4Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates port activity on at least one PHY EXHIBIT 3 7550 CONNECTORS LEDS AND POWER RECEPTACLE ON THE CONNECTOR SIDE EXHIBIT 4 7550 LEDS ON THE FACEPLATE ...

Page 12: ...torage devices into the Storage Area Network SAN using mini SAS HD cable plug connectors Management ports Management is provided using the dual 100 1000BASE T Ethernet ports accessible from two right angle RJ 45 connectors or the RS 232 serial header console port accessible from the serial RJ 45 connector LED indicators LED indicators can be viewed from the connector side and the front side of the...

Page 13: ...icates FC traffic on the port and OFF indicates no port activity Fibre Channel Port Speed A bi color FC port speed LED is lit as follows Yellow 32Gb s Green 16Gb s and OFF 8Gb s SAS SATA Device Activity A lit green LED for each SAS connector indicates port activity on at least one EXHIBIT 5 7600 CONNECTORS LEDS AND POWER RECEPTACLE ON THE CONNECTOR SIDE Exhibit 6 7600 LEDS ON THE FACEPLATE ...

Page 14: ... so may cause injury or damage the unit If you are using a rack Properly ground the XstreamCORE to the rack equipment The earth ground connection must be maintained The power requirements plus the power draw of the other equipment in the rack must not overload the supply circuit and or wiring of the rack 8 Wait for the XstreamCORE Ready LED to light indicating that the XstreamCORE has completed it...

Page 15: ...d password The default values are user name root and password Password The user name is case insensitive and the password is case sensitive It is best practice to change the default user name and password Refer to Modify passwords 3 The XstreamVIEW status page appears Continue to Map Devices Installation and Removal of Power Supply Modules 1 To remove a power supply module first remove the power c...

Page 16: ...owing options View all settings to ensure they are appropriate for your configuration Keep the automatic settings created when you powered up your Fibre storage controller and do nothing accepting all the default settings for all ports Use the individual pages listed on the side menu to make changes or use other features such as Email notification or SNMP as needed Port configurations 1 Follow the...

Page 17: ...ted RAID device mapping When using the XstreamCORE FC 7550 or XstreamCORE FC 7600 with a device that supports multiple LUNs behind a target such as a RAID array you must disable SAS Mapping by Topology 1 If you are not already in the XstreamVIEW interface type the IP address of your XstreamCORE into a standard browser 2 Click on the Advanced menu item on the left side of the screen 3 The Advanced ...

Page 18: ... appears 3 From the XstreamVIEW main menu click on the Mapping menu item on the left side of the screen 4 The Mapping page appears If your storage supports SMP the XstreamVIEW System Manager will display mapping information for your devices If your devices do not support SMP you will be able to use the AutoMap feature to map your storage devices AutoMap devices 1 If you are not already in the Xstr...

Page 19: ...temperature conditions Power supply status conditions Messages may state that a device is not working a medium has an error or a command has been stopped You may designate which warning level a recipient receives For example a recipient with a critical severity level only receives critical messages and not warning or informational messages In both monitoring systems you select the warning levels f...

Page 20: ...n Using XstreamVIEW System Manager click Enter Here type in your user name and password and click OK 2 On the left hand menu click Remote Management 3 The Remote Management page appears 4 Click on the enabled radio button next to the SNMP heading 5 Click on the appropriate radio button for SNMP Traps SNMP Extended Traps 6 SNMP Traps and SNMP Extended Traps are notifications for SNMP functions such...

Page 21: ...with an error condition that may have been caused by a flaw in the target device s physical medium or its recorded data Power Supply Down Critical Yes Yes A power supply has powered down or was down after unit power up Temperature Info Yes Yes The unit s internal temperature has increased or decreased to within standard operating ranges Temperature Critical Yes Yes Unit s internal temperature has ...

Page 22: ...treamCORE in a standard browser as found in Using XstreamVIEW System Manager click Enter Here type in your user name and password and click OK 2 On the left hand menu click Remote Management 3 The Remote Management page appears 4 Click on the enabled radio button next to the Email Notification heading 5 Type in the SMTP Server IP address 6 Type in the user name and password of your SMTP Email acco...

Page 23: ...evision number Using XstreamVIEW 1 If you are not already in the XstreamVIEW interface type the IP address of your XstreamCORE in a standard browser as found in Using XstreamVIEW System Manager click Enter Here type in your user name and password and click OK 2 Click on the Firmware Update menu item on the left hand side of the page 3 The Firmware Update page appears Click the Browse or Choose Fil...

Page 24: ... the user name and password values The default values are user name root and password Password The user name is case insensitive and password is case sensitive It is best practice to change user names and passwords Refer to Modify passwords 4 The Status page appears Each page can be reached through the menu at the side of each page An image on each page s header shows each port in the product face...

Page 25: ...he Ready prompt and press Enter If a list of all available commands does not appear on the screen review the steps in this section check the cable or contact service personnel until the problem is solved If you have difficulty using the serial port verify that you have the correct settings and that your serial cable is less then two meters in length Using Telnet Up to three Telnet sessions can be ...

Page 26: ...s Fibre Channel technology offers a variety of cabling options The type of cable required varies depending upon the application environment distance and product Cable Type 32Gb s 16Gb s 8Gb s 62 5 µm OM1 15m 21m 70m 50 µm OM2 35m 50m 150m 50 µm OM3 100m 150m 380m 50 µm OM4 125m 190m 400m Long wave Single Mode 10 000m 10 000m 10 000m Long wave operation requires long wave SFP modules not supplied S...

Page 27: ... value of a parameter or configuration setting It may require a SaveConfiguration command and a restart of the system before it is implemented The restart can be accomplished as part of the SaveConfiguration command or by using a separate FirmwareRestart command A number of set commands may be issued before the SaveConfiguration command Responses to set commands are either an error message or Read...

Page 28: ...le AutoMap automap BootFibreDelay 0 set bootfibredelay 15 ControllerLun enabled get controllerlun ControllerModel get controllermodel ControllerName set controllername Omega6 ClearCLILog ClearCliLog ClearEventLog cleareventlog CoreDumpInfo CoreDumpInfo DataMoverStats get DataMoverStats all Date set date 03 03 2003 DeleteAllMaps deleteallmaps DisplayInitiators DisplayInitiators DumpCLILog DumpCliLo...

Page 29: ...AddLUN HostGroupName lun HGCreate HGCreate HostGroupName HGDelete HGDelete HostGroupName all HGDisplay HGDisplay HostGroupName all HGMapping get HGMapping HGRemoveInitiator HGRemoveInitiator HostGroupName WWN HGRemoveLUN HGRemoveLUN HostGroupName lun HGRename HGRename PrevHostGroupName NewHostGroupName IdentifyController disabled set identifycontroller enabled IdentifyLUN IdentifyLUN lun Info info...

Page 30: ...sasconnectorinfo all SASEnclosures sasenclosures 1 SASMapByTopology setsasmapbytopology enabled SASPortList sasportlist SASTargets sastargets SaveConfiguration saveconfiguration restart SerialNumber get serialnumber SerialPortBaudRate 115200 set serialportbaudrate 19200 SerialPortEcho enabled get seriallportecho SNMP disabled set SNMP enabled SNMPDumpMIB snmpdumpmib SNMPExtendedTraps disabled get ...

Page 31: ...lerLun controls the automatic generation of a controller device at LUN 0 After enabling or disabling the controller LUN save configuration and run automap to re map all devices set ControllerLun enabled disabled get ControllerLun ControllerModel ControllerModel reports the specific model and firmware information to the CLI get ControllerModel ControllerName OEM Configurable Disabled on Error Contr...

Page 32: ...ail address not more than 128 characters long set EmailFromAddress full email address get EmailFromAddress EmailNotify EmailNotify turns on and off email notification Default is disabled Default disabled set EmailNotify enabled disabled get EmailNotify EmailNotifyAddress EmailNotifyAddress configures notification addresses Index is a number between 1 and 5 inclusive Full email address is a fully q...

Page 33: ...t FCSCSIBusyStatus This option controls reporting of either a BUSY or QUEUE FULL status at a point in time when SCSI commands cannot be accepted set FCSCSIBusyStatus busy qfull Requires a SaveConfiguration Restart command get FCSCSIBusyStatus FCSFPInfo FCSFPInfo displays information about the specified Fibre Channel SFP get FCSFPInfo fp all FCWWName FCWWName reports the World Wide Node Name of the...

Page 34: ...numeric characters dashes and underscores are allowed Usage HGRename PrevHostGroupName NewHostGroupName IdentifyController IdentifyController causes the Alert LED to blink to enable identification of this system Disable this option to cancel the blinking Default disabled set IdentifyController enabled disabled get IdentifyController IdentifyLUN Lights the LED s of disk drive s associated with one ...

Page 35: ...urns the name the contents of the first record of the OEM configuration file stored in persistent memory get oemconfigfile OpTempWarn Regulates displays the number of degrees in Celsius before a warning is sent to the user Valid entries are between 0 degrees and 15 degrees Default 10 set OpTempWarn 0 15 Requires a SaveConfiguration Restart command get OpTempWarn Password Specifies password for all...

Page 36: ...nectorInfo displays information about the specified SAS connector Valid connector names are A through D get SASConnectorInfo sasConn all SASEnclosures Immediate Disabled on Error Supported In Band Displays a list of attached enclosures If no arguments are specified only the enclosure summary table is displayed If PHYID is specified this displays connection details for active PHYs If SlotMap is spe...

Page 37: ...te MIB is dumped For further assistance with SNMP consult your network administrator Usage SNMPDumpMIB Controller Product SMI TC SNMPExtendedTraps Controls Extended SNMP trap functioning such as device transition and device error Consult your network administrator for further assistance with SNMP Default disabled set SNMPExtendedTraps enabled disabled get SNMPExtendedTraps SNMPTrapAddress OEM Conf...

Page 38: ... in the format HH MM When SNTP is enabled applies the time zone setting to the time retrieved from a specified SNTP time server to determine local time Default EST set TimeZone EST CST MST PST HH MM Requires a SaveConfiguration command get TimeZone Uptime Returns the time days hrs min sec since the last reboot get Uptime Username Specifies user name for all Telnet FTP and XstreamVIEW user manageme...

Page 39: ... radio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Compliance with ICES 003 This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada Compliance with EN Regulations Marking by the symbol indicates complianc...

Page 40: ...uipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Compliance with ICES 003 This Class A digital apparatus complies with Canadian...

Page 41: ...s applicable of the EMC and Product Safety authorities as indicated below Safety CU 72141224 04 EN 60950 1 CE CSA 60950 1 UL 60950 1 CB IEC60950 1 all national deviations Emissions Immunity FCC Part 15 Class A ICES 003 CE EN55032 EN55024 IEC61000 3 2 IEC61000 3 3 ...

Page 42: ...TED WARRANTY IS MADE IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED ATTO DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT IMPLIED WARRANTIES CANNOT BE EXCLUDED SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD APPLICABLE TO THE PRODUCT BECAUSE SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON THE DURATION ...

Reviews: