Operation
Hammer Jet may only be operated by personnel, who have read and understood this Operating Manual.
Relevant product training could cover the following subjects:
•
Operation of the Hammer Jet
•
Fuel mix and refuelling procedures
•
Maintenance procedures, hereunder air filter replacement
•
Turbine module replacement
•
Machine safety
•
Transport and storage
Safety Instructions
WARNING
Fire hazard
Do not use the Hammer Jet indoors or close to flammable material.
Hot exhaust air/safety distance
The outlet temperature next to the turbine is 350 to 550˚C. Keep a distance of at least 5
m from the machine during operation.
Hearing and eye protection
The personnel in the immediate vicinity of the Hammer Jet must use hearing protection
and safety goggles, when operating the Hammer Jet.
CAUTION
Fuel
Use Exxsol D80 or Shellsol D70 petroleum/Kerosene along with 3 % ATT Turbine oil
(7000-80) in the mixing ratio 1 to 30. (20 litres of fuel to 0.6 litre of ATT Turbine oil).
When utilizing US Gallons, the mixing ratio is 0.6 litre ATT Turbine Oil to 5 US Gallons of
Kerosene
Nozzle
Always check the nozzle for damages, cracks or constrictions before use.
Keep under supervision
Do not power up and leave the Hammer Jet unsupervised.
Do not transport the Hammer Jet before it has cooled down completely.
Transport and storage