MC22LV SERIES
– MASTER CLOCKS
REV 3/17/15
APPLIED TECHNICAL SYSTEMS
PAGE 23
REVIEWING THE ANNUAL PLAN PROGRAM - Press ANNUAL [A] key then [ENTER]. Press
ANNUAL [A] key again repeatedly to review each Annual plan.
SETTING THE OUTPUT PULSE
– Press [5] then [ENTER]. Enter a pulse length from 0 to 9 for
Relay 1 Press [ENTER]. Enter the pulse length from 0 to 9 for Relay 2. Press [ENTER].
0 = Pulse OFF.
SELECTING SLEEP MODE
– Press [4][5] then [ENTER] to enter the sleep mode. Press [4][5]
then [ENTER] again to exit the sleep mode.