Electronic Controls & Startup Procedures
ALARM CONDITIONS
U.V. lamp Detector and Timer circuit board Lamp
Operation and Alarm features:
• MONTH LED (Green)- Number of months remaining
before the lamp has to be replaced.
• DAY LED (Orange)- Number of days remaining before
the lamp has to be replaced.
• ALARM LED (Red)- Indicates a problem with the U.V.
Lamp (lamp may be out or beyond its rated life). Blinking
decimal point indicates a properly functioning unit.
Negative number indicates the lamp is beyond its rated
life.
• LO- Indicates the lamp is out and must be replaced.
Beeping Alarm- Indicates problem or lamp life will expire
soon. Continuous Alarm- Lamp has expired or is off
• SILENCE ALARM- Press the reset button. There are a
limited number of snoozes allowed.
• NEW LAMP RESET- Press and hold RESET button
after 8 seconds “re” will appear, continue holding until 12
appears on the display.
OPERATING INSTRUCTIONS
Your U.V. System is equipped to provide a continuous
monitoring system of the U.V. lamp operational status. This
is also equipped with an internal and external fused surge
protection system. This solid-state electronic circuit board
provides the latest in U.V. lamp monitoring technology.
U.V. LAMP CONTROL START UP PROCEDURE
1. Make sure the U.V. lamp is inserted per instructions
into the quartz sleeve and U.V. chamber. Then plug the
U.V. lamp into the end-lamp connectors.
2. Plug the unit into a 120V wall plug outlet.
3. Upon start up the U.V. lamp Detector and Timer
circuit board will perform a self diagnostic test.
• Quick Beep
• Software version is displayed (Fig. 1)
• Type of ballast is displayed
• Watts: (Fig 2)
8gpm = approx 25
12gpm = approx 40
20gpm = approx 45
• The number 12 is displayed representing 12 months
remaining
• Green LED on, blinking decimal point to the right =
System Check OK, U.V. System is operational. (Fig. 3)
RESET LAMP
Set the 1 Year Lamp Timer – WITH NEW U.V. LAMP
Make sure the control box is plugged into the wall outlet
and the U.V. lamp is on. Press and hold the reset button.
Hold the reset button down for approximately 8 seconds
until you see “re”, continue holding until you see the
number 12 and hear it beep. At this point release the
button. The 1 year lamp timer has just been reset. (Fig 4)
GDS ©2019 • www.aquat.com
Summary of Contents for GDS-12
Page 2: ...GDS 2016 2 ...
Page 7: ...GDS 2016 7 Installation Diagram GDS 2019 www aquat com ...
Page 17: ...GDS 2016 17 Circuit Board Layout GDS 2019 www aquat com ...
Page 21: ...GDS 2016 21 Specifications GDS 2019 www aquat com ...
Page 22: ...GDS 2016 22 Notes GDS 2019 www aquat com ...