CHAPTER 4
Troubleshooting & Diagnostics
4.1 General
This chapter presents information related to the Wirespan 600 / 610
diagnostics functions. The information presented in this chapter include:
z
User-controlled test functions
z
Troubleshooting
4.2 User-Controlled Test Functions
Loopback Function
The user-controlled test functions are activated by means of the
buttons and LCD screen.
Digital Loopback
Pressing Loopback button on top panel of WireSpan 610 or find the
function in Menu-tree of WireSpan 600. The digital loopback returns the
data sent by the remote E1 equipment towards the remote E1 equipment.
In case, clock reference source will change to E1 automatically. Signal
path shown in
Figure 4-1
.On Main menu screen you can find “DL” to
confirm setting surely.
This test checks the connections between two E1 equipments, and the
local E1 link port interface.
4-1