POWER PLANT
P 3
NOV 98
100
1.16
.
30
- Ensures minimum propeller speed control, on ground and at low power (see
propeller governing).
- Delivers, in case of engine failure at take-off, automatic uptrimmed take-off power
to the valid engine (ATPCS) by responding to the signal generated by the
Auto-Feather Unit (AFU) of the failed engine.
- Controls the modulated opening of the Handling Bleed valve (HBV) so as to ensure
correct LP compressor operation.
PROPELLER VALVE MODULE (PVM)
- At high power, controls the propeller maximum speed Np, according to the PWR
MGT selection.
- Controls propeller pitch at low power and when using reverse.
- Ensures low pitch through a solenoid (when PLA are below FI position).
PWR MGT SELECTOR
LINE A
: One engine out operation
LINE B
: Normal TO or CLB
LINE C
: CRZ
Note : Sensible sector designed to allow fix throttle engine control