3. Hardware Installation
Prepare necessary cables, hub, power cord and RS-232/RS-485 connector.
Place GW51W-
MAXI
to the area that an access point can cover.
Connect a serial device to a serial port of GW51W-
MAXI
, make sure the right connection of either
RS-232 or RS-485.
Plug in DC-9-30V, the buzzer will beep and the RUN LED will blink if GW51W-
MAXI
functions normally.
Please refer to Appendix A.5 to see all of LED messages.
Use
monitor.exe
configuration utility in the product CD or diskette to diagnose GW51W-
MAXI
. If it starts
up successfully, you are able to find the IP and MAC addresses of GW51W-
MAXI
. You can change the
network parameters of GW51W-
MAXI
to join your LAN by changing its IP address, gateway IP address
and subnet mask.
Note:
If there are more than one access points, the access point’s ESSID must be the same.
3.1 Configuration
Atop GW51W-
MAXI
Serial-Ethernet Server is shipped with default settings shown in the following table:
Property
Default Value
IP Address
10.0.50.100
Gateway
10.0.0.254
Subnet Mask
255.255.0.0
User Name
admin
Password
Null
COM 1
9600,None, 8, 1, No flow control, buffer disabled, packet delimiter timer 1ms
Link 1
Type: TCP Server, Listen port 4660, Filter=0.0.0.0, Virtual COM disabled
SysName of SNMP
name
SysLocation of SNMP
location
SysContact of SNMP
contact
NOTE:
Atop provides a default button to restore system settings including IP address, gateway IP address
and subnet mask etc. to the defaults. Press and hold the default button for 5 seconds till the server
reboots.
3.2 Assigning a new IP Address by ARP command
Arp –s is used to assign a static IP address of GW51W-
MAXI
and add this static entries to the Arp cache of
the computer, when TCP/IP packet with destination port number 1 is sent to GW51W-
MAXI
, it causes the
device to check its MAC address with IP address, once GW51W-
MAXI
finds those two unmatched, it will
reboot and change to the new IP address which was set by Arp –s command. The following example uses
ARP to assign a static IP address of GW51W-
MAXI
using its MAC address printed on the label of the rear
panel, then use Telnet to send the TCP/IP packet with destination port number 1 to GW51W-
MAXI
, after
All rights reserved. Designed in Taiwan.